WAYNESBORO, PA —
OSHA Inspection: HOMES BY KEYSTONE, INCORPORATED
Planned inspection · Health discipline
At a glance
On , OSHA opened a planned health inspection of HOMES BY KEYSTONE, INCORPORATED in 13338 MIDVALE ROAD, WAYNESBORO, PA 17268 (NAICS 321992). OSHA activity number 112985932.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- HOMES BY KEYSTONE, INCORPORATED
- Site address
- 13338 MIDVALE ROAD
- City
- WAYNESBORO
- State
- PA
- ZIP
- 17268
- Mailing
- P.O. BOX 69, WAYNESBORO, PA 17268
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Health
- Advance notice
- No
- Union status
- N
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 321992
- SIC code (legacy)
- 2452
- Employees
- 93
- Ownership type
- A
- Industry flags
- Manufacturing health.
Citations
11 citations on file for this inspection.
5(a)(1)
- Issued
- Sep 5, 2003
- Abate by
- Oct 8, 2003
- Penalty
- Initial $675 · Current $335 Reduced
General-duty citation text
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to potential crushing injuries while working under the suspended roof assemblies: (a)Roof Section - Employee(s) were working under a roof assembly that was suspended above the floor by chains that were not approved for overhead lifting and by a spreader bar that was connected to two (2) hoists. The spreader bar was not marked with the rated load and the weight of the spreader bar. Two (2) "A- frame" secondary support units were in place under the suspended roof assembly, but these units were also not marked with their rated load capacity. The employer did not have engineering documentation to demonstrate that these devices, along with the overhead beam that supported the hoists, were adequately designed and there were no inspection records maintained to ensure the integrity of the lifting assembly , on or about July 17, 2003. AMONG OTHER METHODS, ONE FEASIBLE AND ACCEPTABLE ABATEMENT METHOD TO CORRECT THIS HAZARD IS TO BUILD THE ROOF SYSTEMS DIRECTLY ON THE HOUSING UNIT, OR TO HAVE AN ENGINEERING STUDY PERFORMED ON THE ENTIRE LIFTING SYSTEM AND SECONDARY SUPPORTS TO ENSURE THIS DESIGN CAN ADEQUATELY SUPPORT THE LOAD. REPLACE THE CHAINS WITH A GRADE 80 ALLOY CHAIN THAT IS DESIGNED FOR OVERHEAD LIFTING. CONDUCT PERIODIC INSPECTIONS ON THE LIFTING DEVICES AS PER ANSI B30.16 - 1973, OVERHEAD HOISTS, AND ASME B30.20-1999, BELOW-THE-HOOK LIFTING DEVICES. THE NAMEPLATE FOR THE SPREADER BAR SHOULD HAVE THE MANUFACTURER'S NAME AND ADDRESS, THE SERIAL NUMBER, THE LIFTER WEIGHT, AND THE RATED LOAD. VERIFICATION REQUIRED
Recent events (2)
- — F (S) $335.00
- — Z (S) $675.00
5(a)(1)
- Issued
- Sep 5, 2003
- Abate by
- Jan 15, 2004
- Penalty
- Initial $675 · Current $335 Reduced
General-duty citation text
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to severe burn injuries from the potential dust explosion hazard that could have resulted from, or have been exacerbated by, the location of the dust collector inside of the building, the lack of deflagration venting on the dust collector, the lack of magnetic separators or equivalent means to prevent the entry of tramp metal into the dust collection system, the lack of designated smoking areas, and not ensuring that the filtered air was not recirculated back into the plant: (a)Homes by Keystone, Incorporated; Dust Collector Room - The Torit dust collector that was used to collect combustible wood dust was located inside of the building in a separate room, but the dust collector was not equipped with deflagration venting, on or about July 17, 2003. (b)Homes by Keystone, Incorporated - Magnetic separators or similar devices were not provided to prevent the entry of tramp metal into the dust collection system from the floor and equipment intakes located in the Cabinet Shop, on row about July 17, 2003. (c)Homes by Keystone, Incorporated - Smoking was not restricted to designated areas, on or about July 17, 2003. (d)Homes by Keystone, Incorporated - Adequate measures were not in place to ensure that the filtered air was not recycled back into the building, on or about July 25, 2003 AMONG OTHER METHODS, ONE FEASIBLE AND ACCEPTABLE ABATEMENT METHOD TO CORRECT THESE HAZARDS INCLUDES FOLLOWING NFPA 664, STANDARD FOR PREVENTION OF FIRES AND EXPLOSIONS IN WOOD PROCESSING AND WOODWORKING FACILITIES, 1998 EDITION, INCLUDING BUT NOT LIMITED TO: LOCATE THE DUST COLLECTOR OUTSIDE OF THE BUILDING, INSTALL DEFLAGRATION VENTING IN THE DUST COLLECTOR, INSTALL MAGNETIC SEPARATORS OR OTHER SIMILAR DEVICES TO PREVENT TRAMP METAL FROM ENTERING THE DUST COLLECTION SYSTEM, DESIGNATE SPECIFIC SAFE AREAS FOR SMOKING, AND ENSURE THAT THE FILTERED AIR IS NOT RECYCLED BACK INTO THE BUILDING. VERIFICATION REQUIREDTION
Recent events (2)
- — F (S) $335.00
- — Z (S) $675.00
1910.22 A01
- Issued
- Sep 5, 2003
- Abate by
- Oct 8, 2003
- Penalty
- Initial $675 · Current $335 Reduced
Recent events (2)
- — F (S) $335.00
- — Z (S) $675.00
1910.1200 H03 III
- Issued
- Sep 5, 2003
- Abate by
- Sep 10, 2003
Recent events (2)
- — F (S)
- — Z (S)
1910.23 C01
- Issued
- Sep 5, 2003
- Abate by
- Jan 15, 2004
- Penalty
- Initial $675 · Current $335 Reduced
Recent events (2)
- — F (S) $335.00
- — Z (S) $675.00
1910.242 B
- Issued
- Sep 5, 2003
- Abate by
- Jul 17, 2003
- Penalty
- Initial $570 · Current $300 Reduced
Recent events (2)
- — F (S) $300.00
- — Z (S) $570.00
1910.303 G02 I
- Issued
- Sep 5, 2003
- Abate by
- Jan 15, 2004
- Penalty
- Initial $675 · Current $335 Reduced
Recent events (2)
- — F (S) $335.00
- — Z (S) $675.00
1910.305 A02 IIIF
- Issued
- Sep 5, 2003
- Abate by
- Jan 15, 2004
Recent events (2)
- — F (S)
- — Z (S)
1910.307 B
- Issued
- Sep 5, 2003
- Abate by
- Jan 15, 2004
- Penalty
- Initial $675 · Current $335 Reduced
Recent events (2)
- — F (S) $335.00
- — Z (S) $675.00
1910.95 C01
- Issued
- Sep 5, 2003
- Abate by
- Oct 8, 2003
8111
Recent events (2)
- — F (O)
- — Z (O)
1910.147 C06 I
- Issued
- Sep 5, 2003
- Abate by
- Oct 8, 2003
Recent events (2)
- — F (O)
- — Z (O)
More inspections at Homes by Keystone, Incorporated
View Homes by Keystone, Incorporated's full OSHA safety record →
More inspections in this industry (NAICS 321992)
More inspections in PA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 112985932.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.