Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: EXCEL HOMES

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of EXCEL HOMES in R.R. #2, BOX 683, LIVERPOOL, PA 17045 (NAICS 321992). OSHA activity number 112986823.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Excel Homes — free Get an email when a new federal OSHA severe-injury report for Excel Homes is published. One employer, no account, unsubscribe in one click.
Establishment
EXCEL HOMES
Site address
R.R. #2, BOX 683
City
LIVERPOOL
State
PA
ZIP
17045
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
N
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
321992
SIC code (legacy)
2452
Employees
324
Ownership type
A
Industry flags
Manufacturing safety.

9 citations on file for this inspection.

5(a)(1)

Serious Gravity 10 5 instances 6 exposed
Issued
Jun 7, 2006
Abate by
Jul 10, 2006
Penalty
Initial $5,000 · Current $5,000
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The
employer did not furnish employment
and a place of employment which were free from recognized hazards that
were causing or likely to cause
death or serious physical harm to employees in that employees were exposed
to a potential crushing injury
from falling roof assemblies and/or catwalks resulting from deficient
hoists.
(a)Final Finish Catwalk Number 2 - The hoist chain was worn beyond safe
operation and the
motor brake disc and spline were worn, or about May 9, 2006.
(b)B Half Floors - The beam capacity was not marked and/or legible from
floor level; the hoist
chain was worn beyond safe operation; the push button station was damaged
and the cord
insulation was torn, on or about May 9, 2006.
(c)Above Catwalk Number 4 - There were no end stops for the hoist motors
and the beam
capacity was not marked and/or legible from floor level, on or about May
9, 2006.
(d)B Roof - There were multiple hoists operating on the hoist beam and
there were no stops to
prevent one hoist from striking another and the push button station had a
broken housing, on
or about May 6, 2006.
(e)Shingle Buggy - The hoist chain was worn beyond safe operation and the
shunt on the hoist
brake was broken, on or about May 9, 2006.
AMONG OTHER METHODS, ONE FEASIBLE AND ACCEPTABLE ABATEMENT  METHOD
TO CORRECT THESE HAZARDS WOULD BE TO ENSURE THAT THE HOISTS MEET THE
REQUIREMENTS OF "ANSI B30.16, OVERHEAD HOISTS", AND THAT DEFECTS ARE
REPAIRED AS SOON AS POSSIBLE.
Recent events (2)
  • — F (S) $5000.00
  • — Z (S) $5000.00

1910.22 A01

Serious Gravity 02 1 instance 3 exposed
Issued
Jun 7, 2006
Abate by
Jul 3, 2006
Penalty
Initial $1,500 · Current $1,500
Recent events (2)
  • — F (S) $1500.00
  • — Z (S) $1500.00

1910.147 C04 I

Serious Gravity 03 1 instance 2 exposed
Issued
Jun 7, 2006
Abate by
Jul 3, 2006
Penalty
Initial $1,875 · Current $1,875
Recent events (2)
  • — F (S) $1875.00
  • — Z (S) $1875.00

1910.305 B02

Serious Gravity 02 1 instance 3 exposed
Issued
Jun 7, 2006
Abate by
Jul 3, 2006
Penalty
Initial $1,500 · Current $1,500
Recent events (2)
  • — F (S) $1500.00
  • — Z (S) $1500.00

5(a)(1)

Serious Gravity 01 1 instance 1 exposed
Issued
Jun 7, 2006
Abate by
Jul 3, 2006
Penalty
Initial $7,500 · Current $1,000 Reduced
Section 5(a)1 of the Occupational Safety and Health Act of 1970:  The
employer did not
furnish employment and a place of employment which was free from
recognized hazards that
were likely to cause serious physical harm to employees in that the
employees responsible for
performing work installing plumbing and other electrical equipment on the
tops of the units
were exposed to a slip and fall hazard.  This slip/fall hazard involves
the risk of slipping off
of the joists or rafters and falling onto the top of the unit.  Such work
should be performed
within a controlled access zone by trained employees, and employees
performing such work
should wear appropriate footwear.
Recent events (2)
  • — F (S) $1000.00
  • — Z (S) $7500.00

1910.23 C01

Repeat Gravity 03 1 instance 6 exposed
Issued
Jun 7, 2006
Abate by
Jul 3, 2006
Penalty
Initial $12,500 · Current $6,250 Reduced
Recent events (2)
  • — F (R) $6250.00
  • — Z (R) $12500.00

1910.132 A

Deleted Repeat Gravity 01 1 instance 1 exposed
Issued
Jun 7, 2006
Abate by
Jul 3, 2006
Penalty
Initial $7,500 · Current $7,500
Recent events (2)
  • — F (R) $7500.00
  • — Z (R) $7500.00

1910.22 D01

Other-than-serious Gravity 01 1 instance 2 exposed
Issued
Jun 7, 2006
Abate by
Jul 3, 2006
Recent events (2)
  • — F (O)
  • — Z (O)

1910.157 E02

Other-than-serious Gravity 01 1 instance 1 exposed
Issued
Jun 7, 2006
Abate by
Jul 3, 2006
Recent events (2)
  • — F (O)
  • — Z (O)

View Excel Homes's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 112986823.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.