OSHA Inspection: WOODS CONSTRUCTION

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of WOODS CONSTRUCTION in ROUTE 98, FAIRVIEW, PA 16142 (NAICS 238160). OSHA activity number 113174361.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Woods Construction — free Get an email when a new federal OSHA severe-injury report for Woods Construction is published. One employer, no account, unsubscribe in one click.
Establishment
WOODS CONSTRUCTION
Site address
ROUTE 98
City
FAIRVIEW
State
PA
ZIP
16142
Mailing
1512 SARANAC DRIVE, TRANSFER, PA 16154
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
N
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238160
SIC code (legacy)
1761
Employees
4
Ownership type
A

3 citations on file for this inspection.

1926.501 B13

Serious Gravity 02 2 instances 2 exposed
Issued
Sep 1, 2006
Abate by
Sep 28, 2006
Penalty
Initial $800 · Current $800

5(a)(1)

Repeat Gravity 05 1 instance 2 exposed
Issued
Sep 1, 2006
Abate by
Sep 28, 2006
Penalty
Initial $2,800 · Current $2,800
Section 5(a)(1) of the Occupational Safety and Health Act of 1970:  The
employer did not furnish employment
and a place of employment which were free from recognized hazards that
were causing or likely to cause
death or serious physical harm to employees in that employees were exposed
to
the hazards associated with
erecting roof trusses:
(a)  Condos, third set from Route 98, Fairview, PA;  The bracing of the
roof trusses was
inadequate because the only continuous bracing between the trusses was the
spacers between
each truss.  There was one diagonal brace attached at the peak which
extends sideways across
the trusses to almost the middle of the roof, on the east side of the
condo.  There were no
lateral braces at all.
AMONG OTHER METHODS, ONE FEASIBLE AND ACCEPTABLE METHOD OF ABATEMENT
WOULD BE TO FOLLOW THE MANUFACTURER'S RECOMMENDATION ON ROOF TRUSS
ERECTION OR THE BCSI-103 ISSUE FROM THE TRUSS PLATE INSTITUTE.
WOODS CONSTRUCTION WAS PREVIOUSLY CITED FOR A VIOLATION OF THE OCCUPATIONAL
SAFETY AND HEALTH STANDARD OR ITS EQUIVALENT, 5(a)(1), WHICH WAS CONTAINED
IN
OSHA INSPECTION NUMBER 113175269, CITATION NUMBER 1, ITEM NUMBER 1, ISSUED
JUNE
29, 2006.

1926.405 A02 III

Repeat Gravity 01 1 instance 2 exposed
Issued
Sep 1, 2006
Abate by
Sep 28, 2006
Penalty
Initial $200 · Current $200

View Woods Construction's full OSHA safety record →