OSHA Inspection: PENNSYLVANIA ELECTRIC COMPANY

Accident-driven inspection · Safety discipline

On , OSHA opened an accident-driven safety inspection of PENNSYLVANIA ELECTRIC COMPANY in PHILIPSBURG SUB-DISTRICT, PHILIPSBURG, PA 16866 (NAICS 000000). OSHA activity number 113341523.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Pennsylvania Electric Company — free Get an email when a new federal OSHA severe-injury report for Pennsylvania Electric Company is published. One employer, no account, unsubscribe in one click.
Site address
PHILIPSBURG SUB-DISTRICT
City
PHILIPSBURG
State
PA
ZIP
16866
Mailing
1001 BROAD STREET, JOHNSTOWN, PA 15907
Inspection type
Accident-driven (A)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
Y
Opened
Closing conference
Case closed
Data loaded
NAICS code
000000
SIC code (legacy)
4911
Employees
27
Ownership type
A
Industry flags
Manufacturing safety.

1 citation on file for this inspection.

5(a)(1)

Deleted Serious Gravity 10 1 instance 2 exposed
Issued
Mar 31, 1994
Abate by
Apr 23, 1994
Penalty
Initial $6,300
Section 5(a)(1) of the Occupational Safety and Health Act of 1970:
The employer did not furnish employment and a place of employment
which were free from recognized hazards that were causing or likely
to cause serious physical harm to employee in that persons were
exposed to serious injuries from falls while climbing poles and/or
structures during evaluation/training:
a)Penelec Training Center, Philipsburg, PA  Persons were
required to climb a 40 foot high pole and an Hstructure
to a height of approximately 30 feet while using only a
lineman's body belt/safety belt; there was no personal
fall arrest equipment worn or utilized and a "buddy
system" of rescue was not utilized.
Among other methods, one feasible and acceptable abatement method
to correct this hazard would be:
1)  Persons undergoing training in climbing heights in excess of 4
feet be required to use personal fall arrest equipment.
2)  Use of a "buddy system" so as the person climbing is monitored
by another person in the immediate vicinity who is equipped with
climbing gear to assist in the event of distress.
IN THE ALTERNATIVE...
29 CFR 1910.132(a):  Protective equipment was not used when
necessary whenever hazards capable of causing injury and impairment
were encountered:
a)Penelec Training Center, Philipsburg, PA  Persons
were required to climb a 40 foot high pole and an
Hstructure to a height of approximately 30 feet
while using only a linesman's body belt/safety
belt; there was no personal fall arrest equipment
worn or utilized and a "buddy system" of rescue was
not utilized.
Recent events (2)
  • — J (S)
  • — Z (S) $6300.00

View Pennsylvania Electric Company's full OSHA safety record →