Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: BEACON TOWER SERVICE INC.

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of BEACON TOWER SERVICE INC. in 800 SOUTH STREET, WALTHAM, MA 02154 (NAICS 000000). OSHA activity number 113545883.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Beacon Tower Service INC. — free Get an email when a new federal OSHA severe-injury report for Beacon Tower Service INC. is published. One employer, no account, unsubscribe in one click.
Site address
800 SOUTH STREET
City
WALTHAM
State
MA
ZIP
02154
Mailing
P.O.BOX 3507, BROCKTON, MA 02304
Inspection type
Referral (C)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
N
Opened
Closing conference
Case closed
Data loaded
NAICS code
000000
SIC code (legacy)
1731
Employees
4
Ownership type
A

1 citation on file for this inspection.

5(a)(1)

Serious Gravity 10 1 instance 1 exposed
Issued
Aug 23, 1999
Abate by
Aug 26, 1999
Penalty
Initial $1,500 · Current $1,500
Section 5(a)(1) of the Occupational Safety and Health Act of 1970:  The
employer did not
furnish employment and a place of employment which were free from
recognized hazards that
were causing or likely to cause death or serious physical harm to
employees in that employees
were exposed to the hazard of being crushed:
(a) Location - 800 South St., Waltham, MA:
On or about 6/16/99, an employee was exposed to and received serious
crushing injuries
when a radio tower, 300 feet high, weighing 14,000 lbs., was raised off
its cement pad
approximately 20 inches with two 10 ton hydraulic jacks to replace the
damaged base
insulator while an employee was cleaning underneath.
Among other methods, feasible and acceptable to correct this hazard
include, but are not
limited to the following:
a. Utilize a long handle brush so as bit to have any body parts under the
load.
b. Follow manufacturer's recommendation (safety information) to block
raised loads.

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 113545883.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.