CUTLER, ME —
OSHA Inspection: NATIONAL STEEL ERECTORS CORPORATION
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of NATIONAL STEEL ERECTORS CORPORATION in TOWER SIX, CUTLER, ME 04626 (NAICS 238120). OSHA activity number 113796437.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- NATIONAL STEEL ERECTORS CORPORATION
- Site address
- TOWER SIX
- City
- CUTLER
- State
- ME
- ZIP
- 04626
- Mailing
- P.O. BOX 709, MUSKOGEE, OK 74402
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- Y
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Data loaded
Establishment context
- NAICS code
- 238120
- SIC code (legacy)
- 1791
- Employees
- 6
- Ownership type
- A
Citations
1 citation on file for this inspection.
5(a)(1)
- Issued
- Aug 20, 2003
- Abate by
- Aug 28, 2003
- Penalty
- Initial $875 · Current $875
General-duty citation text
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to falls from elevated tower(s) and personnel platform(s) due to improperly erected and/or maintained hoisting equipment: In the following instances hoisting equipment was not properly erected and/or maintained: a)Tower 6 - The hoist line used to raise or lower employees was not equipped with a swivel to prevent rotation of employees. b)Tower 6 - The personnel load capacity and material capacity of the lifting system was not posted at the hoist operator station. c)Tower 6 - The lifting capacity and drawings of the gin pole were not available at the job site. d)Tower 6 - The hoist was not level. e)Tower 6 - The recommended operating speeds and special hazard warnings or instructions were not posted on the hoist. f)Tower 6 - Hoist exhaust pipes were not guarded. g)Tower 6 - An accessible fire extinguisher was not available at the hoist operator station. h)Tower 6 - The operating manual or manufacturer's information for the hoist was not maintained at the job site. Among other methods, one feasible and acceptable abatement method to correct this hazard is to follow the applicable ANSI and manufactures information.
More inspections at National Steel Erectors Corporation
View National Steel Erectors Corporation's full OSHA safety record →
More inspections in this industry (NAICS 238120)
More inspections in ME
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 113796437.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.