ST. LOUIS, MO —
OSHA Inspection: EASTERN STAR GRAND CHAPTER OF MISSOURI
Accident-driven inspection · Safety discipline
At a glance
On , OSHA opened an accident-driven safety inspection of EASTERN STAR GRAND CHAPTER OF MISSOURI in 3681 LINDELL, ST. LOUIS, MO 63108 (NAICS 000000). OSHA activity number 113890859.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- EASTERN STAR GRAND CHAPTER OF MISSOURI
- Site address
- 3681 LINDELL
- City
- ST. LOUIS
- State
- MO
- ZIP
- 63108
What kind of inspection was it?
- Inspection type
- Accident-driven (A)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- N
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Data loaded
Establishment context
- NAICS code
- 000000
- SIC code (legacy)
- 8641
- Employees
- 4
- Ownership type
- A
Citations
1 citation on file for this inspection.
5(a)(1)
- Issued
- Jun 3, 1998
- Abate by
- Jul 21, 1998
- Penalty
- Initial $750 · Current $750
General-duty citation text
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that: (a) Employees who were expected to use the unlocking device on the elevator had not received training in safe procedures such as, but not limited to, the following: 1)Checking to assure location of elevator. 2)Safe operation of the emergency device key and procedure to open the elevator door. 3)Awareness training for the fall hazard. (b)The unlocking device was available to persons other than maintenance or authorized persons. While ultimate responsibility for correcting the hazard rests with the employer, given his/her superior knowledge of the work place, feasible and acceptable methods to correct this hazard, among others, are: (1)The qualified person(s) to use the emergency device to open the doors should be trained by a recognized elevator service company or trained in accordance with ANSI Standards and City elevator inspection procedures. The established procedure should be written. (2)In the absence of a qualified person to open the doors, the elevator service company should be summoned. Reference materials: American National Standard Safety Code for Elevators Dumbwaiters Escalators and Moving Walks; (ANSI A17.1-1971); Rule 111.9e and Rule 111.10.
Recent events (2)
- — I (S) $750.00
- — Z (S) $750.00
More inspections in this industry (NAICS 000000)
More inspections in MO
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 113890859.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.