RED OAK, IA ·
OSHA Inspection: ROMECH
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of ROMECH in 2700 N. BROADWAY, RED OAK, IA 51566 (NAICS 000000). OSHA activity number 115094047.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- ROMECH
- Site address
- 2700 N. BROADWAY
- City
- RED OAK
- State
- IA
- ZIP
- 51566
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- N
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 000000
- SIC code (legacy)
- 3499
- Employees
- 531
- Ownership type
- A
- Industry flags
- Manufacturing safety.
Citations
2 citations on file for this inspection.
880004
- Issued
- Mar 29, 2001
- Abate by
- Apr 3, 2001
- Penalty
- Initial $2,625 · Current $1,312 Reduced
General-duty citation text
Section 88.4 - Code of Iowa (1999) 88.4: The employer did not furnish employment and a place of employment which was free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to hazards of being caught in the space between the work rest and sanding disk as it was in excess of 3/32 of an inch: (a)Tool & Die Area, Wilton Combination Disc/Belt Sander, Model #4202, Serial #30258, Asset #13080 - The sander had a gap between the work rest and the rotating wheel greater than the manufacturer's specification of 3/32". In addition, the brackets securing the work rest to the machine were insufficient to hold the proper clearance. The excess space created an amputation hazard between the rotating disc and work rest while being used by an employee on November 28, 2000. Among other methods, one feasible and acceptable abatement method to correct the hazard is to assure that the gap between the edge of the table and the face of the disc be of sufficient space (3/32 inch) so as not to allow parts to get caught and assure that worn brackets are immediately replaced as referenced in the operating instructions/parts manual for the Wilton, model 4202, Disc, Belt and Combination Disc/Belt Sanders, pg. 13 and the Employer's Work Station Operation Instruction Sheet, item number 10.
Recent events (2)
- · I (S) $1312.00
- · Z (S) $2625.00
1910.178 L03 IID
- Issued
- Mar 29, 2001
- Abate by
- Apr 3, 2001