OSHA Inspection: J.D. STREETT & CO., INC.

Accident-driven inspection · Health discipline

On , OSHA opened an accident-driven health inspection of J.D. STREETT & CO., INC. in 4055 PARK AVENUE, ST. LOUIS, MO 63110 (NAICS 000000). OSHA activity number 116112194.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch J.D. Streett & CO., INC. — free Get an email when a new federal OSHA severe-injury report for J.D. Streett & CO., INC. is published. One employer, no account, unsubscribe in one click.
Site address
4055 PARK AVENUE
City
ST. LOUIS
State
MO
ZIP
63110
Inspection type
Accident-driven (A)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
Y
Opened
Closing conference
Case closed
Data loaded
NAICS code
000000
SIC code (legacy)
2992
Employees
28
Ownership type
A

3 citations on file for this inspection.

5(a)(1)

Serious Gravity 10 1 instance 2 exposed
Issued
Mar 15, 1996
Abate by
Mar 27, 1996
Penalty
Initial $2,500 · Current $2,500
Section 5(a)(1) of the Occupational Safety and Health Act of 1970:  The
employer did not
furnish employment and a place of employment which were free from
recognized hazards that
were causing or likely to cause death or serious physical harm to
employees in that employees
were exposed to the hazards of fire:
(a)  On September 15, 1995, where two laboratory employees were installing
an Atomic
Absorption Spectrophotometer (AAS). A drain tube was positioned between
the AAS and the
2 1/2 gallon plastic carboy which was used to drain the bottle.  The
carboy was located in a
closed cabinet underneath the AAS.  The manufacturer recommends the drain
bottle be placed
in an open area and not in an enclosure, such as a closed cabinet.
Failure to do so can result
in a build-up of potentially explosive vapors, depending on the solvent
being used.  Following
the manufacturer's recommended procedures would have included proper
placement of the bottle
and ensuring proper positioning of the discharge tube into the bottle.
Among other methods, one feasible and acceptable abatement method to
correct this hazard
would be to properly position the drain bottle outside of the enclosure in
the open area where
the build-up of potentially explosive vapors could not occur.

1910.101 B

Serious Gravity 03 1 instance 2 exposed
Issued
Mar 15, 1996
Abate by
Mar 27, 1996
Penalty
Initial $1,250 · Current $1,250

1910.157 G02

Serious Gravity 10 1 instance 26 exposed
Issued
Mar 15, 1996
Abate by
May 1, 1996
Penalty
Initial $2,500 · Current $2,500