YORK, PA ·
OSHA Inspection: MANLEY VALVE
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of MANLEY VALVE in 400 STATE STREET, YORK, PA 17405 (NAICS 000000). OSHA activity number 116203985.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- MANLEY VALVE
- Site address
- 400 STATE STREET
- City
- YORK
- State
- PA
- ZIP
- 17405
- Mailing
- P.O. BOX 1827, YORK, PA 17405
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- Non-union (N)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Data loaded
Establishment context
- NAICS code
- 000000
- SIC code (legacy)
- 3592
- Employees
- 127
- Ownership type
- Private (A)
- Industry flags
- Manufacturing safety.
Citations
7 citations on file for this inspection.
5(a)(1)
- Issued
- Oct 18, 1999
- Abate by
- Feb 17, 2000
- Penalty
- Initial $1,500 · Current $975 Reduced
General-duty citation text
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to the hazard of the spreader bar breaking and dropping the load causing broken bones and crushing injuries: (a)Forge Department - The spreader bar, used at the annealing furnace, was homemade. The dimensions of the spreader bar were thirty two (32) inches long by two (2) inches thick with a thirty nine (39) inch reach. The thickness of the steel bars was five eighth (5/8) inches. The spreader did not have any capacity marked on it and was showing signs of wear, in that the main support bar was bending. Employees were lifting 400 pounds out of the annealing furnace with the spreader bar. AMONG OTHER METHODS, ONE FEASIBLE AND ACCEPTABLE ABATEMENT METHOD TO CORRECT THIS HAZARD IS TO RATE AND MARK THE CAPACITY OF THE SPREADER BAR. VERIFICATION REQUIREDTION
Recent events (3)
- · P (S) $975.00
- · I (S) $975.00
- · Z (S) $1500.00
1910.147 C04 II
- Issued
- Oct 18, 1999
- Abate by
- Dec 15, 1999
- Penalty
- Initial $1,125 · Current $730 Reduced
Recent events (2)
- · I (S) $730.00
- · Z (S) $1125.00
1910.217 B03 I
- Issued
- Oct 18, 1999
- Abate by
- Dec 15, 1999
- Penalty
- Initial $3,150 · Current $2,050 Reduced
Recent events (2)
- · I (S) $2050.00
- · Z (S) $3150.00
1910.217 B04 I
- Issued
- Oct 18, 1999
- Abate by
- Dec 15, 1999
Recent events (2)
- · I (S)
- · Z (S)
1910.217 E01 I
- Issued
- Oct 18, 1999
- Abate by
- Dec 15, 1999
Recent events (2)
- · I (S)
- · Z (S)
1910.219 B01
- Issued
- Oct 18, 1999
- Abate by
- Nov 15, 1999
- Penalty
- Initial $1,800 · Current $1,170 Reduced
Recent events (2)
- · I (S) $1170.00
- · Z (S) $1800.00
1910.218 B02
- Issued
- Oct 18, 1999
- Abate by
- Dec 30, 1999
- Penalty
- Initial $3,150 · Current $2,045 Reduced
Recent events (2)
- · I (S) $2045.00
- · Z (S) $3150.00
More inspections at Manley Valve
View Manley Valve's full OSHA safety record →
More inspections in this industry (NAICS 000000)
More inspections in PA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 116203985.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.