Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of SPECTRA WOOD in 2651 CAROLEAN INDUSTRIAL DRIVE, STATE COLLEGE, PA 16801 (NAICS 337125). OSHA activity number 116209024.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Spectra Wood — free Get an email when a new federal OSHA severe-injury report for Spectra Wood is published. One employer, no account, unsubscribe in one click.
Establishment
SPECTRA WOOD
Site address
2651 CAROLEAN INDUSTRIAL DRIVE
City
STATE COLLEGE
State
PA
ZIP
16801
Mailing
2651 CAROLEAN INDUSTRIAL DRIVE, STATE COLLEGE, PA 16801
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
N
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
337125
SIC code (legacy)
2499
Employees
110
Ownership type
A
Industry flags
Manufacturing safety.

1 citation on file for this inspection.

5(a)(1)

Serious Gravity 03 4 instances 91 exposed
Issued
Jul 30, 2008
Abate by
Apr 10, 2010
Penalty
Initial $2,000 · Current $1,200 Reduced
Section 5(a)(1) of the Occupational Safety and Health Act of 1970. The
employer did not furnish employment
and a place of employment which were free from recognized hazards that
were causing or likely to cause
death or serious physical harm to employees in that employees were exposed
to potential fire and dust
explosion hazards because methods and practices were not utilized to
properly design dust collectors to prevent
explosions and prevent propagation of a fire/explosion into occupied area:
(a)Outside Cabinet Shop - The Norfab dust collector was not provided with
deflagration vent,
backflash damper and high speed abort gate to minimize pressure
development in the event of
an explosion, on or about May 7, 2008.
(b)Outside Cainet Shop - The Norfab collector system was not grounded and
bonded, on or about
May 7, 2008.
(c)Cabinet Shop, Frame Department - The Dantherm dust collection system
had a capacity of
over 5000 cfm and located inside the building, on or about May 7, 2008.
(d)Cabinet Shop, Frame Department - The Dantherm duct collector system was
not grounded and
bonded, on or about May 7, 2008.
ABATEMENT NOTE: Among other methods, one feasible and acceptable abatement
method to
correct these hazards is to comply with the National Fire Protection
Association (NFPA 664)
"Standards for the Prevention of Fires and Explosion Processing and
Woodworking Facilities" 2007
edition as it applies to your equipment including but not limited to the
following:
* Recycle exhaust air back into the building from dust collector in
accordance to 8.2.2.6
* Locate dust collection equipment in accordance with section 8.2.2.5.1
* Ductwork shall be grounded and bonded in accordance to 7.9.2.
VERIFICATION REQUIRED