STATE COLLEGE, PA —
OSHA Inspection: SPECTRA WOOD
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of SPECTRA WOOD in 2651 CAROLEAN INDUSTRIAL DRIVE, STATE COLLEGE, PA 16801 (NAICS 337125). OSHA activity number 116209024.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- SPECTRA WOOD
- Site address
- 2651 CAROLEAN INDUSTRIAL DRIVE
- City
- STATE COLLEGE
- State
- PA
- ZIP
- 16801
- Mailing
- 2651 CAROLEAN INDUSTRIAL DRIVE, STATE COLLEGE, PA 16801
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- N
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 337125
- SIC code (legacy)
- 2499
- Employees
- 110
- Ownership type
- A
- Industry flags
- Manufacturing safety.
Citations
1 citation on file for this inspection.
5(a)(1)
- Issued
- Jul 30, 2008
- Abate by
- Apr 10, 2010
- Penalty
- Initial $2,000 · Current $1,200 Reduced
General-duty citation text
Section 5(a)(1) of the Occupational Safety and Health Act of 1970. The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to potential fire and dust explosion hazards because methods and practices were not utilized to properly design dust collectors to prevent explosions and prevent propagation of a fire/explosion into occupied area: (a)Outside Cabinet Shop - The Norfab dust collector was not provided with deflagration vent, backflash damper and high speed abort gate to minimize pressure development in the event of an explosion, on or about May 7, 2008. (b)Outside Cainet Shop - The Norfab collector system was not grounded and bonded, on or about May 7, 2008. (c)Cabinet Shop, Frame Department - The Dantherm dust collection system had a capacity of over 5000 cfm and located inside the building, on or about May 7, 2008. (d)Cabinet Shop, Frame Department - The Dantherm duct collector system was not grounded and bonded, on or about May 7, 2008. ABATEMENT NOTE: Among other methods, one feasible and acceptable abatement method to correct these hazards is to comply with the National Fire Protection Association (NFPA 664) "Standards for the Prevention of Fires and Explosion Processing and Woodworking Facilities" 2007 edition as it applies to your equipment including but not limited to the following: * Recycle exhaust air back into the building from dust collector in accordance to 8.2.2.6 * Locate dust collection equipment in accordance with section 8.2.2.5.1 * Ductwork shall be grounded and bonded in accordance to 7.9.2. VERIFICATION REQUIRED
Recent events (3)
- — P (S) $1200.00
- — I (S) $1200.00
- — Z (S) $2000.00
More inspections at Spectra Wood
View Spectra Wood's full OSHA safety record →
More inspections in this industry (NAICS 337125)
More inspections in PA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 116209024.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.