FAYETTEVILLE, GA ·
OSHA Inspection: LATEX CONSTRUCTION COMPANY
Accident-driven inspection · Safety discipline
At a glance
On , OSHA opened an accident-driven safety inspection of LATEX CONSTRUCTION COMPANY in KENWOOD ROAD, FAYETTEVILLE, GA 30210 (NAICS 000000). OSHA activity number 116444308.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- LATEX CONSTRUCTION COMPANY
- Site address
- KENWOOD ROAD
- City
- FAYETTEVILLE
- State
- GA
- ZIP
- 30210
- Mailing
- P.O. BOX 917, CONYERS, GA 30207
What kind of inspection was it?
- Inspection type
- Accident-driven (A)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- Yes
- Union status
- Union (Y)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 000000
- SIC code (legacy)
- 1623
- Employees
- 117
- Ownership type
- Private (A)
- Industry flags
- Construction safety.
Citations
1 citation on file for this inspection.
5(a)(1)
- Issued
- Nov 22, 1996
- Abate by
- Nov 29, 1996
- Penalty
- Initial $5,600 · Current $3,080 Reduced
General-duty citation text
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish to each of his employees employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to: overturning of pipelaying side boom tractors due to excessive loading: a)30" Main Line "A" at Thorton Drive and Kenwood Road in Fayetteville, Georgia: On or about May 30, 1996, four 583K Caterpillar Side Boom Tractors were used to lift and lower a 30" diameter pipe encased in 3.5" concrete, approximately 641.60' long into a 8' X 10' trench in a manner that violated industry standard in that: (1). Side boom tractors #3 and #4 were loaded beyond the maximum load capacity. (2). The handling of the load was not conducted in such a manner to minimize dynamic effects. (3). The load charts were not provided for each operator to inform them of the load ratings. Among other methods, one feasible and acceptable abatement method to correct this hazard is to: 1). Utilize and follow the procedures as outlined in the "Safety Standard for Cableways, Cranes, Derricks, Hoist, Jacks, and Slings," ANSI/ASME B30.14-1991
Recent events (2)
- · I (S) $3080.00
- · Z (S) $5600.00
More inspections at Latex Construction Company