OSHA Inspection: ODOM'S TENNESSEE PRIDE SAUSAGE INC

Complaint inspection · Health discipline

On , OSHA opened a complaint health inspection of ODOM'S TENNESSEE PRIDE SAUSAGE INC in 1201 NEELY'S BEND RD., MADISON, TN 37115 (NAICS 311612). OSHA activity number 120501903.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Odom'S Tennessee Pride Sausage INC — free Get an email when a new federal OSHA severe-injury report for Odom'S Tennessee Pride Sausage INC is published. One employer, no account, unsubscribe in one click.
Site address
1201 NEELY'S BEND RD.
City
MADISON
State
TN
ZIP
37115
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
N
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
311612
SIC code (legacy)
2013
Employees
69
Ownership type
A

15 citations on file for this inspection.

1910.120 Q01

Serious 1 instance 2 exposed
Issued
Sep 23, 2005
Abate by
Oct 29, 2005
Penalty
Initial $1,750 · Current $1,750

Hazardous substances 0170

1910.120 Q02 II

Serious 1 instance 2 exposed
Issued
Sep 23, 2005
Abate by
Oct 29, 2005

Hazardous substances 0170

1910.120 Q02 IV

Serious 1 instance 4 exposed
Issued
Sep 23, 2005
Abate by
Oct 29, 2005

Hazardous substances 0170

1910.120 Q02 V

Serious 1 instance 2 exposed
Issued
Sep 23, 2005
Abate by
Oct 29, 2005

Hazardous substances 0170

1910.120 Q02 X

Serious 1 instance 4 exposed
Issued
Sep 23, 2005
Abate by
Oct 29, 2005

Hazardous substances 0170

1910.120 Q02 XI

Serious 1 instance 2 exposed
Issued
Sep 23, 2005
Abate by
Oct 29, 2005

Hazardous substances 0170

1910.120 Q06 IIIA

Serious 2 instances 2 exposed
Issued
Sep 23, 2005
Abate by
Oct 29, 2005

Hazardous substances 0170

1910.120 Q06 VA

Serious 2 instances 2 exposed
Issued
Sep 23, 2005
Abate by
Oct 29, 2005

Hazardous substances 0170

1910.134 C01

Serious 1 instance 2 exposed
Issued
Sep 23, 2005
Abate by
Oct 29, 2005

Hazardous substances 0170

1910.134 C01 IV

Serious 1 instance 2 exposed
Issued
Sep 23, 2005
Abate by
Oct 29, 2005

Hazardous substances 0170

1910.134 E06 IC

Serious 2 instances 2 exposed
Issued
Sep 23, 2005
Abate by
Oct 29, 2005

Hazardous substances 8880

1910.134 M02 I

Serious 2 instances 2 exposed
Issued
Sep 23, 2005
Abate by
Oct 29, 2005

Hazardous substances 0170

503010501

Serious 1 instance 2 exposed
Issued
Sep 23, 2005
Abate by
Oct 29, 2005

Hazardous substances 0170

T.C.A. 50-3-105(1):  The employer did not furnish employment and a
place of employment which were free from recognized hazards that
were likely to cause death or serious physical harm to employees.
An example on 8/12/05 was the suspect accuracy of the BW
Technologies Gas Alert NH3 portable ammonia monitors used by
Maintenance Personnel to define when it was necessary to don self-
contained breathing apparatus (SCBA) respirators during an ammonia
leak or release situation anywhere in the ammonia refrigeration
system in the plant.  Calibration for the portable monitoring meter
inspected (J 304-A006990, GAXT-A) was "past" (the instrument screen
said "Cal Past").  Page 3 of the user's manual said that the
instrument was to be calibrated at least every 180 days.  The
expiration date given on the ammonia gas cylinder used for
calibration was 8/9/05, so that the cylinder was past its
expiration date on the date of the inspection.
The employer recognized the toxicity of the ammonia, as evidenced
by its material safety data sheets (MSDS's) on that chemical.  He
also recognized the need for protection against exposures to the
gas, as evidenced by his requirement for SCBA use in areas of
ammonia release yielding concentrations over 25 ppm.
The above-listed employees were potentially exposed to ammonia,
which could be released if equipment leaked.  The hazard of
inaccurate portable ammonia monitors was reasonably foreseeable.
Among other methods, one feasible and acceptable abatement method
to correct this hazard is to calibrate the ammonia portable
monitors within the frequency stated by the manufacturer, and to
only utilize calibration gas that is within its expiration date.

1910.1200 H01

Serious 2 instances 2 exposed
Issued
Sep 23, 2005
Abate by
Oct 29, 2005
Penalty
Initial $1,750 · Current $1,750

Hazardous substances 0530

3000327 B 3

Other-than-serious Gravity 00 2 instances 4 exposed
Issued
Sep 23, 2005
Abate by
Oct 29, 2005
Penalty
Initial $500 · Current $500

View Odom'S Tennessee Pride Sausage INC's full OSHA safety record →