OSHA Inspection: INTEC BUILDING SYSTEMS INC.

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of INTEC BUILDING SYSTEMS INC. in RHODES ROAD & STATE ROUTE 59, KENT, OH 44240 (NAICS 000000). OSHA activity number 121940969.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Intec Building Systems INC. — free Get an email when a new federal OSHA severe-injury report for Intec Building Systems INC. is published. One employer, no account, unsubscribe in one click.
Site address
RHODES ROAD & STATE ROUTE 59
City
KENT
State
OH
ZIP
44240
Mailing
870 MOE DRIVE, SUITE A-1, AKRON, OH 44310
Inspection type
Referral (C)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
N
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
000000
SIC code (legacy)
1542
Employees
9
Ownership type
A
Industry flags
Construction safety.

1 citation on file for this inspection.

5(a)(1)

Serious Gravity 10 1 instance 6 exposed
Issued
Aug 3, 1993
Abate by
Aug 6, 1993
Penalty
Initial $750 · Current $525 Reduced
Section 5(a)(1) of the Occupational Safety and Health Act of 1970:  The
employer did not furnish employment and a place of employment which were
free from recognized hazards that were causing or likely to cause death
or serious physical harm to employees in that employees were exposed to:
On or about June 17, 1993, during the erection of a two story office
building at Rhodes Road and State Route 59 in Kent, Ohio, employees were
exposed to the hazards of serious injuries such as lacerations, broken
bones, or death from a roof collapse while installing metal plate
connected
wood trusses approximately 76 feet long on top of 10 feet high wood
bearing
walls.  Inadequate lateral bracing and inadequate top chord diagonal
bracing were used for the truss erection.
The hazards can be abated by, but not limited to, the following:
(a)  Establish proper spacing of both lateral and top chord diagonal
bracing by use of a registered professional engineer for trusses over 60'
in length as recommended by the Truss Plate Institue and/or by utilization
of truss manufacturers recommendations during erection of trusses.
(b)  Utilize proper lifting practices for truss length over 60' per Truss
Plate Institute, or per gang nail warning literature provided with trusses
during delivery.
(c)  Assure permanent bracing is installed prior to placing loads of OSB
(Oriented Strand Board) or piggy back cap trusses on top of installed
trusses.
Recent events (2)
  • — I (S) $525.00
  • — Z (S) $750.00

View Intec Building Systems INC.'s full OSHA safety record →