CLEVES, OH —
OSHA Inspection: STOCK MFG. & DESIGN CO., INC.
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of STOCK MFG. & DESIGN CO., INC. in 10040 CILLEY RD., CLEVES, OH 45002 (NAICS 000000). OSHA activity number 121982649.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- STOCK MFG. & DESIGN CO., INC.
- Site address
- 10040 CILLEY RD.
- City
- CLEVES
- State
- OH
- ZIP
- 45002
- Mailing
- P.O. BOX. 68, CLEVES, OH 45002
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- N
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 000000
- SIC code (legacy)
- 3548
- Employees
- 45
- Ownership type
- A
Citations
1 citation on file for this inspection.
5(a)(1)
- Issued
- May 26, 1999
- Abate by
- Jun 28, 1999
- Penalty
- Initial $2,500 · Current $1,600 Reduced
General-duty citation text
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to being struck by swinging loads and loads falling off the hoists due to broken and/or fallen components of the hoists, hooks and the below the hook attachments, in that: (a)Operators turning tanks such as the T-90 tanks, used a 1 ton hoist without assuring adequate manuevering space or adequate procedures to avoid being struck by swinging loads. Below the hook lifting devices such as but not limited to; the five made in house by Stock Mfg. used to lift tanks such as the T-60s, 90s and T-120s on the 5 ton and the 1 ton hoists in the Hi- Bay had not been load tested nor were they identified with the following information, manufacturer's name and address, serial number, and rated load prior to use. Among feasible abatement method to correct the hazards, is to ensure through procedures and training that the load be raised in such a manner as to minimize swinging, and operators position themselves in such a manner as to minimize exposure to being struck by the load. Further, to conduct periodic and frequent inspections of all hoist, hooks, and below-the-hook lifting devices to ensure that hoists, hooks and below the hook attachments are free from recognized hazards as required by ASME B30-20c-1998, and prior to initial use of all new, altered, modified or repaired below-the-hook lifting devicing should be tested and inspected under the direction of a qualified person and a written report be furnished by such a person as required by addenda to ASME B30.20-1993 for Below-the-Hook lifting devices, by ASME B30.10-1993, hooks, and as required by ASME B30.16-1993 for Overhead Hoists (Underhung).
Recent events (2)
- — I (S) $1600.00
- — Z (S) $2500.00
More inspections at Stock MFG. & Design CO., INC.
View Stock MFG. & Design CO., INC.'s full OSHA safety record →
More inspections in this industry (NAICS 000000)
More inspections in OH
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 121982649.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.