LEBANON, OH —
OSHA Inspection: VICKERS ELECTRONIC SYSTEMS INC.
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of VICKERS ELECTRONIC SYSTEMS INC. in 211 WALNUT STREET, LEBANON, OH 45036 (NAICS 000000). OSHA activity number 121987374.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- VICKERS ELECTRONIC SYSTEMS INC.
- Site address
- 211 WALNUT STREET
- City
- LEBANON
- State
- OH
- ZIP
- 45036
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- N
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Data loaded
Establishment context
- NAICS code
- 000000
- SIC code (legacy)
- 3541
- Employees
- 24
- Ownership type
- A
- Industry flags
- Manufacturing safety.
Citations
13 citations on file for this inspection.
5(a)(1)
- Issued
- Apr 24, 1998
- Abate by
- Jun 11, 1998
- Penalty
- Initial $5,000 · Current $1,500 Reduced
General-duty citation text
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that: Employees working in the vicinity of the hoists were exposed to the hazards of falling loads, hoists, and their components due to the following conditions: (a)Hoist located in Bay #4 had the following defects: The start and stop buttons on the pendant control, when depressed, caused the hoist to drift and the brake to not hold. The pendant had missing screws, leaving openings. (b)Hoist located in the bay #3 had no identification markings on the pendant and the pendant cover screws were missing leaving openings. (c)On or about 11-25-97, the hoist located in Bay #4 was being operated with wire rope cable which was not of sufficient length to maintain 2 wraps on the drum.. One feasible and acceptable method, among others, to correct these hazards is: Establishing a preventative maintenance program, which includes conducting frequent and periodic inspections by a competent person on all hoists and hoist components and support structures with corrective measures taken as needed.
Recent events (2)
- — I (S) $1500.00
- — Z (S) $5000.00
1910.23 C01
- Issued
- Apr 24, 1998
- Abate by
- Jun 11, 1998
- Penalty
- Initial $2,500 · Current $1,500 Reduced
Recent events (2)
- — I (S) $1500.00
- — Z (S) $2500.00
1910.176 B
- Issued
- Apr 24, 1998
- Abate by
- Jun 11, 1998
- Penalty
- Initial $2,500 · Current $1,500 Reduced
Recent events (2)
- — I (S) $1500.00
- — Z (S) $2500.00
1910.178 Q07
- Issued
- Apr 24, 1998
- Abate by
- May 6, 1998
- Penalty
- Initial $2,000 · Current $1,000 Reduced
Recent events (2)
- — I (S) $1000.00
- — Z (S) $2000.00
1910.179 B06 I
- Issued
- Apr 24, 1998
- Abate by
- May 13, 1998
- Penalty
- Initial $2,000 · Current $1,000 Reduced
Recent events (2)
- — I (S) $1000.00
- — Z (S) $2000.00
1910.179 F04 VII
- Issued
- Apr 24, 1998
- Abate by
- May 20, 1998
- Penalty
- Initial $3,500 · Current $1,000 Reduced
Recent events (2)
- — I (S) $1000.00
- — Z (S) $3500.00
1910.179 I
- Issued
- Apr 24, 1998
- Abate by
- May 20, 1998
- Penalty
- Initial $2,500 · Current $2,500
Recent events (2)
- — I (S) $2500.00
- — Z (S) $2500.00
1910.179 J02 III
- Issued
- Apr 24, 1998
- Abate by
- Apr 29, 1998
- Penalty
- Initial $5,000 · Current $2,500 Reduced
Recent events (2)
- — I (S) $2500.00
- — Z (S) $5000.00
1910.179 L01
- Issued
- Apr 24, 1998
- Abate by
- Jun 11, 1998
- Penalty
- Initial $5,000 · Current $2,500 Reduced
Recent events (2)
- — I (S) $2500.00
- — Z (S) $5000.00
1910.179 M01
- Issued
- Apr 24, 1998
- Abate by
- May 20, 1998
- Penalty
- Initial $2,500 · Current $1,000 Reduced
Recent events (2)
- — I (S) $1000.00
- — Z (S) $2500.00
1910.219 C04 I
- Issued
- Apr 24, 1998
- Abate by
- May 20, 1998
- Penalty
- Initial $2,500 · Current $1,000 Reduced
Recent events (2)
- — I (S) $1000.00
- — Z (S) $2500.00
1910.219 E03 I
- Issued
- Apr 24, 1998
- Abate by
- May 20, 1998
- Penalty
- Initial $2,500 · Current $1,000 Reduced
Recent events (2)
- — I (S) $1000.00
- — Z (S) $2500.00
1910.178 A06
- Issued
- Apr 24, 1998
- Abate by
- May 6, 1998
Recent events (2)
- — I (O)
- — Z (O)
More inspections at Vickers Electronic Systems INC.