DE PERE, WI ·
OSHA Inspection: PORT CITY STRUCTURES, INC.
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of PORT CITY STRUCTURES, INC. in 1415 LAWRENCE DR., DE PERE, WI 54115 (NAICS 236220). OSHA activity number 122018104.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- PORT CITY STRUCTURES, INC.
- Site address
- 1415 LAWRENCE DR.
- City
- DE PERE
- State
- WI
- ZIP
- 54115
- Mailing
- 2006 WERY LN, GREEN BAY, WI 54313
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- N
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 236220
- SIC code (legacy)
- 1542
- Employees
- 12
- Ownership type
- A
Citations
2 citations on file for this inspection.
5(a)(1)
- Issued
- Sep 14, 2007
- Abate by
- Sep 18, 2007
- Penalty
- Initial $1,500 · Current $1,500
General-duty citation text
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employmnent and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to falling trusses: a) On August 21, 2007, employees working on the roof and inside of the fitness center building on Lawrence Drive were exposed to the hazard of truss collapse due to the lack of adequate diagonal truss bracing. Among other methods, feasible and acceptable abatement methods to correct this hazard would be to: Comply with the October, 2006 Building Component Safety Information Guide to Good Practice for Handling, Installing, Restraining, and Bracing of Metal Plate Connected Wood Trusses: " It is critical to note that all lateral restraint must be stabilized by diagonal bracing installed in the same plane. Lateral restraint by itself is not adequate without the added rigidity of triangulation from the diagonal bracing." No Abatement Certification or Abatement Documentation required.tion
1926.501 B10
- Issued
- Sep 14, 2007
- Abate by
- Sep 18, 2007
- Penalty
- Initial $750 · Current $750
More inspections in this industry (NAICS 236220)
More inspections in WI
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 122018104.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.