ALLENTOWN, PA ·
OSHA Inspection: KEYSTONE DODGE INC.
Planned inspection · Health discipline
At a glance
On , OSHA opened a planned health inspection of KEYSTONE DODGE INC. in 2250 LEHIGH ST., ALLENTOWN, PA 18103 (NAICS 000000). OSHA activity number 122028848.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- KEYSTONE DODGE INC.
- Site address
- 2250 LEHIGH ST.
- City
- ALLENTOWN
- State
- PA
- ZIP
- 18103
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Health
- Advance notice
- No
- Union status
- Non-union (N)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Data loaded
Establishment context
- NAICS code
- 000000
- SIC code (legacy)
- 5511
- Employees
- 50
- Ownership type
- Private (A)
- Industry flags
- Manufacturing health.
Citations
18 citations on file for this inspection.
5(a)(1)
- Issued
- Jul 10, 1997
- Abate by
- Jul 13, 1997
- Penalty
- Initial $875 · Current $440 Reduced
General-duty citation text
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to fractures and crushing injuries: a) Service Shop: The Gilbarco double post hydraulic car lifts located in bays #2, #5, #6, #8, and #9 were observed in use with employees standing underneath vehicles on the lift and adequate safety controls were not implemented. A lift automatic locking device was not installed to function as an independent mechanical lock, nor were alternative safeguards (e.g. - properly rated and placed jack stands) in place to ensure safe operation of this equipment. b) Service Shop: A Weever single post hydraulic car lift located adjacent to the car reconditioning bay was observed in use with an employee standing underneath the vehicle on the lift. The vehicle was being extended using blocks rather than the extenders provided with the car lift and as recommended by the manufacturer. ABATEMENT NOTE: Among other methods, one feasible and acceptable abatement method to correct this hazard is to comply with the most recent edition of the American National Standard, Safety Requirements for the construction, care and use of automotive lifts (ANSI B1531). In the event a section is "grandfathered" by the ANSI Standard, then alternative safeguards which provide equivalent or greater employee safety needs to be implemented by the employer.ed
Recent events (2)
- · I (S) $440.00
- · Z (S) $875.00
1910.132 D02
- Issued
- Jul 10, 1997
- Abate by
- Aug 31, 1997
- Penalty
- Initial $875 · Current $440 Reduced
Recent events (2)
- · I (S) $440.00
- · Z (S) $875.00
1910.132 F04
- Issued
- Jul 10, 1997
- Abate by
- Aug 31, 1997
Recent events (2)
- · I (S)
- · Z (S)
1910.133 A01
- Issued
- Jul 10, 1997
- Abate by
- Jul 18, 1997
1910.304 F05 V
- Issued
- Jul 10, 1997
- Abate by
- Jul 13, 1997
- Penalty
- Initial $446 · Current $220 Reduced
Recent events (2)
- · I (S) $220.00
- · Z (S) $446.00
1910.305 B01
- Issued
- Jul 10, 1997
- Abate by
- Jul 13, 1997
- Penalty
- Initial $446 · Current $220 Reduced
Recent events (2)
- · I (S) $220.00
- · Z (S) $446.00
1910.307 B
- Issued
- Jul 10, 1997
- Abate by
- Aug 31, 1997
- Penalty
- Initial $525 · Current $280 Reduced
Recent events (2)
- · I (S) $280.00
- · Z (S) $525.00
1910.106 E02 IVD
- Issued
- Jul 10, 1997
- Abate by
- Jul 23, 1997
1340
1910.106 E09 III
- Issued
- Jul 10, 1997
- Abate by
- Jul 13, 1997
1910.147 C01
- Issued
- Jul 10, 1997
- Abate by
- Aug 31, 1997
Recent events (2)
- · I (O)
- · Z (O)
1910.147 C06 I
- Issued
- Jul 10, 1997
- Abate by
- Aug 31, 1997
Recent events (2)
- · I (O)
- · Z (O)
1910.157 G01
- Issued
- Jul 10, 1997
- Abate by
- Aug 31, 1997
Recent events (2)
- · I (O)
- · Z (O)
1910.253 B02 II
- Issued
- Jul 10, 1997
- Abate by
- Jul 13, 1997
1910.253 B02 IV
- Issued
- Jul 10, 1997
- Abate by
- Jul 13, 1997
1910.253 B04 III
- Issued
- Jul 10, 1997
- Abate by
- Jul 13, 1997
1910.303 G01 I
- Issued
- Jul 10, 1997
- Abate by
- Jul 13, 1997
1910.1200 F05 I
- Issued
- Jul 10, 1997
- Abate by
- Jul 13, 1997
0710
1910.1200 F05 II
- Issued
- Jul 10, 1997
- Abate by
- Jul 15, 1997