Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,196,991Inspections Most recent open 2026-08-24 Last loaded 2026-08-27

OSHA Inspection: D.G. COUNCIL REALTY

Complaint inspection · Health discipline

On , OSHA opened a complaint health inspection of D.G. COUNCIL REALTY in 1404 S. WASHINGTON, KAUFMAN, TX 75142 (NAICS 000000). OSHA activity number 122177983.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch D.G. Council Realty for free Get an email when a new federal OSHA severe-injury report for D.G. Council Realty is published. One employer, no account, unsubscribe in one click.
Establishment
D.G. COUNCIL REALTY
Site address
1404 S. WASHINGTON
City
KAUFMAN
State
TX
ZIP
75142
Mailing
P.O. BOX 111, KAUFMAN, TX 75142
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
Non-union (N)
Opened
Closing conference
Case closed
Data loaded
NAICS code
000000
SIC code (legacy)
6519
Employees
3
Ownership type
Private (A)
Industry flags
Manufacturing health.

2 citations on file for this inspection.

5(a)(1)

Serious Gravity 10 5 instances 6 exposed
Issued
Sep 12, 2001
Abate by
Sep 17, 2001
Penalty
Initial $1,500 · Current $750 Reduced
Section 5(a)(1) of the Occupational Safety and Health Act of 1970:  The
employer and the
building owner did not furnish employmnent and a place of employment which
were free from
recognized hazards that were causing or likely to cause death or serious
physical harm to
employees in that employees were exposed to:
On or about May 24, 2001, employees who worked inside the general
merchandise store were
exposed to the hazards associated with failing structural members and
possible building collapse.
a. The concrete floor had several large cracks and breaks that compromised
the integrity of the
structure.
b. The panel board was exposed to water due to a leaking roof creating the
hazard of
electrocution.
c. The concrete block exterior wall had several severe cracks and breaks
that compromised the
integrity of the structure.  The concrete blocks in the wall near the
storage area on the back wall
of the store had separated as much as approximately 2 inches.
Methods of correction for each hazard include the following:
a) Repair the concrete foundation such that it is sound and capable of
supporting the intended
load.
b) Repair the damaged portions of the roof and flooring so that they are
sound, tight, and have
no defects that admit water.
c) Replace broken concrete blocks and apply caulking in the concrete block
mortar.
Recent events (2)
  • · I (S) $750.00
  • · Z (S) $1500.00

1910.1001 J02 I

Serious Gravity 10 1 instance 6 exposed
Issued
Sep 12, 2001
Abate by
Sep 17, 2001
Penalty
Initial $1,500
Recent events (2)
  • · I (S)
  • · Z (S) $1500.00

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 122177983.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.