MOUNT ENTERPRISE, TX —
OSHA Inspection: HAMON COOLING TOWERS, INC.
Accident-driven inspection · Safety discipline
At a glance
On , OSHA opened an accident-driven safety inspection of HAMON COOLING TOWERS, INC. in HWY. 315 & CR 3122, MOUNT ENTERPRISE, TX 75681 (NAICS 000000). OSHA activity number 122185275.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- HAMON COOLING TOWERS, INC.
- Site address
- HWY. 315 & CR 3122
- City
- MOUNT ENTERPRISE
- State
- TX
- ZIP
- 75681
- Mailing
- P.O. BOX 1500, SOMERVILLE, NJ 08876
What kind of inspection was it?
- Inspection type
- Accident-driven (A)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- N
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 000000
- SIC code (legacy)
- 1796
- Employees
- 23
- Ownership type
- A
Citations
3 citations on file for this inspection.
5(a)(1)
- Issued
- Dec 27, 2000
- Abate by
- Jan 9, 2001
- Penalty
- Initial $3,000
General-duty citation text
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to falls from elevations: On or about Friday, June 30, 2000, Mount Enterprise, Texas; employees working on the construction of a cooling tower at the Tenaska Gateway Generating Station were permitted to enter and exit a man-basket work platform, mounted on the forks of a Lull, 6K-37, rough terrain fork lift, while the basket was elevated approximately 30-feet above the ground. Among other methods, recognized means of abatement include, but are not limited to: Lowering the platform to floor (ground) level for personnel to enter and exit, as required by the American Society of Mechanical Engineers (ASME) standard B56.6 - 1992 ( Safety Standard for Rough Terrain Forklift Trucks), Part III, chapter 5 (General Safety Practices), section 5.15.1 (Elevating Personnel), paragraph (w).graph
Recent events (2)
- — F (S)
- — Z (S) $3000.00
1926.451 C02 IV
- Issued
- Dec 27, 2000
- Abate by
- Jan 24, 2001
- Penalty
- Initial $4,200 · Current $4,200
Recent events (2)
- — F (S) $4200.00
- — Z (S) $4200.00
1926.451 C02 V
- Issued
- Dec 27, 2000
- Abate by
- Jan 9, 2001
- Penalty
- Initial $4,200
Recent events (2)
- — F (S)
- — Z (S) $4200.00
More inspections at Hamon Cooling Towers, INC.
View Hamon Cooling Towers, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 000000)
More inspections in TX
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 122185275.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.