BARTONVILLE, IL —
OSHA Inspection: KEYSTONE CONSOLIDATED INDUSTRIES, INC. D/B/A/ KEYS
Referral inspection · Health discipline
At a glance
On , OSHA opened a referral health inspection of KEYSTONE CONSOLIDATED INDUSTRIES, INC. D/B/A/ KEYS in 7000 S.W. ADAMS ST., BARTONVILLE, IL 61607 (NAICS 000000). OSHA activity number 122199433.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- KEYSTONE CONSOLIDATED INDUSTRIES, INC. D/B/A/ KEYS
- Site address
- 7000 S.W. ADAMS ST.
- City
- BARTONVILLE
- State
- IL
- ZIP
- 61607
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Health
- Advance notice
- No
- Union status
- Y
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 000000
- SIC code (legacy)
- 3321
- Employees
- 1200
- Ownership type
- A
Citations
1 citation on file for this inspection.
5(a)(1)
- Issued
- May 31, 2002
- Abate by
- Jun 5, 2002
- Penalty
- Initial $2,125 · Current $2,125
1900
General-duty citation text
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to: On and before March 5, 2002, employees in the Continuous Caster Area were exposed to the hazard of asphyxiation in that, compressed Nitrogen was used in the piping system and the employer did not clearly identify the contents of the piping system. One feasible and effective method of abatement would be to ensure that all piping systems are marked with an appropriate legend meeting the color and size requirements of ASME/ANSI A 13.1-1996, Scheme for the Identification of Piping Systems. Positive identification of the contents of a piping system shall be by lettered legend giving the name of the contents in full or abbreviated form. Legends shall be applied close to valves, flanges, and adjacent to changes in direction, branches, and where pipes pass through walls and floors and at intervals on straight pipe sufficient for identification.
Recent events (2)
- — I (U) $2125.00
- — Z (S) $2125.00
More inspections at Keystone Consolidated Industries, INC. D/B/A/ Keys
View Keystone Consolidated Industries, INC. D/B/A/ Keys's full OSHA safety record →