Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,195,903Inspections Most recent open 2026-08-18 Last loaded 2026-08-21

OSHA Inspection: F.T.G. MFG. INC.

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of F.T.G. MFG. INC. in 117-119 BROAD ST., GLOVERSVILLE, NY 12078 (NAICS 000000). OSHA activity number 122245640.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch F.T.G. MFG. INC. for free Get an email when a new federal OSHA severe-injury report for F.T.G. MFG. INC. is published. One employer, no account, unsubscribe in one click.
Establishment
F.T.G. MFG. INC.
Site address
117-119 BROAD ST.
City
GLOVERSVILLE
State
NY
ZIP
12078
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
Non-union (N)
Opened
Closing conference
Case closed
Data loaded
NAICS code
000000
SIC code (legacy)
2842
Employees
15
Ownership type
Private (A)

4 citations on file for this inspection.

5(a)(1)

Serious Gravity 03 2 instances 4 exposed
Issued
Apr 12, 1995
Abate by
Apr 17, 1995
Penalty
Initial $375 · Current $375
Section 5(a)(1) of the Occupational Safety and Health Act of 1970:  The
employer did not
furnish employment and a place of employment which were free from
recognized hazards that
were causing or likely to cause death or serious physical harm to
employees in that employees
were exposed to the hazard of falling into an open elevator shaft when
doors are accidentally
opened due to the lack of properly operating door interlocks:
(a)At F.T.G. Mfg., Broad Street, second and third floor, the elevator
interlock for
the door was not working properly at either floor allowing the door to be
potentially
opened when the elevator is not present.  On the second floor, a bolt that
was part of the
interlock was loose and on the third floor, a bolt that was part of the
interlock was
missing, on or about 3/3/95.
Among other methods feasible methods to eliminate this hazard is to insure
that elevators
are in safe operating condition by utilizing the New York State Department
of Labor Industrial
Code Rule 8.  Elements include, but are not limited to:
All manually operated hoistway doors or gates shall be provided with an
interlock or
electric contact as specified in section 8-1.55(b) of the code which
states any force or forces used
to perform any interlocking function shall be so arranged that their
failure to cause the
interlocking action will prevent the movement of the car.
Additionally, in accordance with section 8-1.7(a) and (b):  All parts of
the elevator
machinery, the hoistway gates and doors and car safeties, shall be
maintained in a safe condition
and freight elevators shall be inspected in time intervals to conform with
current New York State
code.  Inspection reports showing date of inspection and condition of the
elevator and hoistway
shall be prepared and signed by the person making such inspection; the
reports shall be made
on a form provided by and with such information as required by the
Industrial Commissioner
and shall be kept on file for examination.  A report by a recognized
casualty company will be
acceptable in lieu of the above if it contains the required information.
Additionally, in accordance with section 8-1.8(a) and (b)  All elevator
cars shall have a
sign posted conspicuously, which shall show the maximum rated load that
can be carried on
the elevator and all freight elevator cars shall have a sign posted
conspicuously, reading as
follows:  "PASSENGERS NOT PERMITTED".

1910.147 C07 I

Other-than-serious Gravity 02 1 instance
Issued
Apr 12, 1995
Abate by
Apr 17, 1995
Penalty
Initial $300
Recent events (2)
  • · I (O)
  • · Z (S) $300.00

1910.178 L

Other-than-serious Gravity 00 1 instance 2 exposed
Issued
Apr 12, 1995
Abate by
Apr 17, 1995

1910.178 P01

Other-than-serious Gravity 01 1 instance 3 exposed
Issued
Apr 12, 1995
Abate by
Apr 17, 1995

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 122245640.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.