Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: MONSON NICHOLAS, INC.

Planned inspection · Health discipline

On , OSHA opened a planned health inspection of MONSON NICHOLAS, INC. in 601 WEST WELLS, MILWAUKEE, WI 53203 (NAICS 000000). OSHA activity number 122413305.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Monson Nicholas, INC. — free Get an email when a new federal OSHA severe-injury report for Monson Nicholas, INC. is published. One employer, no account, unsubscribe in one click.
Site address
601 WEST WELLS
City
MILWAUKEE
State
WI
ZIP
53203
Mailing
714 NORTH YALE AVENUE, VILLA PARK, IL 60181
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
Y
Opened
Closing conference
Case closed
Data loaded
NAICS code
000000
SIC code (legacy)
1771
Employees
2
Ownership type
A

1 citation on file for this inspection.

5(a)(1)

Serious Gravity 03 1 instance 2 exposed
Issued
Apr 12, 2001
Abate by
Apr 17, 2001
Penalty
Initial $1,125 · Current $788 Reduced
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The
employer did not furnish
employment and a place of employment which were free from recognized
hazards that were
causing or likely to cause death or serious physical harm to employees in
that:
(a)At the worksite at the Allright Parking structure at 601 West Wells,
Milwaukee,
WI 53203, the worker was chiseling concrete from the ceiling of the level
above
from a Terex extensible boom platform (self-propelled) and had no personal
fall
arrest system.  Among feasible abatement would be to comply with the
American
National Standards Institute (ANSI) A92.5 - 1992 Standard for
Boom-Supported
Elevating Platforms and have employees wear fall arrest equipment whenever
they
are in an aerial lift.  Without such protective equipment the worker was
exposed
to the hazard of falling to the concrete about 20 feet below.
No certification required.  Violation Abated.on
Recent events (2)
  • — I (S) $787.50
  • — Z (S) $1125.00

View Monson Nicholas, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 122413305.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.