EAGLE RIVER, WI ·
OSHA Inspection: TANK LIFE SPECIALIST
Referral inspection · Health discipline
At a glance
On , OSHA opened a referral health inspection of TANK LIFE SPECIALIST in 522 WALL STREET CITGO STATION, EAGLE RIVER, WI 54521 (NAICS 000000). OSHA activity number 122475445.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- TANK LIFE SPECIALIST
- Site address
- 522 WALL STREET CITGO STATION
- City
- EAGLE RIVER
- State
- WI
- ZIP
- 54521
- Mailing
- PO BOX 525, EAST TAWAS, MI 48730
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Health
- Advance notice
- No
- Union status
- Non-union (N)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Data loaded
Establishment context
- NAICS code
- 000000
- SIC code (legacy)
- 7699
- Employees
- 5
- Ownership type
- Private (A)
Citations
23 citations on file for this inspection.
5(a)(1)
- Issued
- Oct 9, 1997
- Abate by
- Nov 26, 1997
- Penalty
- Initial $225 · Current $90 Reduced
1340
General-duty citation text
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to: a) On 7/31/97, at the Citgo Service Station on Wall St. in Eagle River WI, an employee entering and cleaning gasoline residue from the #1 gasoline underground storage tank was exposed to gasoline vapors at a level of 3140 mg/m3 during a 35 minute sampling period while inside of the tank. b) On 7/31/97, at the Citgo Service Station on Wall St. in Eagle River WI, an employee entering and cleaning gasoline residue from the #3 gasoline underground storage tank was exposed to gasoline vapors at a level of 7672 mg/m3 during a 41 minute sampling period while inside of the tank. The American Conference of Governmental Industrial Hygienists has established a threshold limit value (TLV) for gasoline of 1480 mg/m3 to prevent acute central nervous system depression and mucous membrane and ocular irritation. Feasible methods of control applicable in these circumstance include, but are not limited to the following: 1) Additional ventilation of the tank prior to entry. 2) Representative monitoring of gasoline vapor exposure with a calibrated device sensitive enough to detect toxic levels of gasoline vapors and taking appropriate administrative actions based on those readings.
Recent events (2)
- · I (S) $90.00
- · Z (S) $225.00
1910.95 B01
- Issued
- Oct 9, 1997
- Abate by
- Feb 15, 1998
- Penalty
- Initial $525 · Current $210 Reduced
81108111
Recent events (3)
- · P (S) $210.00
- · I (S) $210.00
- · Z (S) $525.00
1910.95 C01
- Issued
- Oct 9, 1997
- Abate by
- Feb 15, 1998
81108111
Recent events (3)
- · P (S)
- · I (S)
- · Z (S)
1910.134 B06
- Issued
- Oct 9, 1997
- Abate by
- Nov 26, 1997
- Penalty
- Initial $375 · Current $150 Reduced
032009211340
Recent events (2)
- · I (S) $150.00
- · Z (S) $375.00
1910.134 B11
- Issued
- Oct 9, 1997
- Abate by
- Nov 26, 1997
134003200921
Recent events (2)
- · I (S)
- · Z (S)
1910.134 D02 II
- Issued
- Oct 9, 1997
- Abate by
- Nov 26, 1997
0560
Recent events (2)
- · I (S)
- · Z (S)
1910.134 E05
- Issued
- Oct 9, 1997
- Abate by
- Nov 26, 1997
9010
Recent events (2)
- · I (S)
- · Z (S)
1910.134 F02 IV
- Issued
- Oct 9, 1997
- Abate by
- Nov 26, 1997
092103201340
Recent events (2)
- · I (S)
- · Z (S)
1910.146 C04
- Issued
- Oct 9, 1997
- Abate by
- Nov 26, 1997
- Penalty
- Initial $375 · Current $150 Reduced
134009210320
Recent events (2)
- · I (S) $150.00
- · Z (S) $375.00
1910.146 D05 II
- Issued
- Oct 9, 1997
- Abate by
- Nov 26, 1997
1340
Recent events (2)
- · I (S)
- · Z (S)
1910.146 K03
- Issued
- Oct 9, 1997
- Abate by
- Nov 26, 1997
134009210320
Recent events (2)
- · I (S)
- · Z (S)
1910.1000 C
- Issued
- Oct 9, 1997
- Abate by
- Nov 26, 1997
- Penalty
- Initial $300 · Current $120 Reduced
9010
Recent events (2)
- · I (S) $120.00
- · Z (S) $300.00
1910.1000 E
- Issued
- Oct 9, 1997
- Abate by
- Nov 26, 1997
9010
Recent events (2)
- · I (S)
- · Z (S)
1910.1028 C01
- Issued
- Oct 9, 1997
- Abate by
- Nov 26, 1997
- Penalty
- Initial $300 · Current $120 Reduced
0320
Recent events (2)
- · I (S) $120.00
- · Z (S) $300.00
1910.1028 C02
- Issued
- Oct 9, 1997
- Abate by
- Nov 26, 1997
Recent events (2)
- · I (S)
- · Z (S)
1910.1028 E02 I
- Issued
- Oct 9, 1997
- Abate by
- Oct 15, 1997
0320
Recent events (2)
- · I (S)
- · Z (S)
1910.1028 F02 I
- Issued
- Oct 9, 1997
- Abate by
- Nov 26, 1997
Recent events (2)
- · I (S)
- · Z (S)
1910.1028 J01 I
- Issued
- Oct 9, 1997
- Abate by
- Nov 26, 1997
0320
Recent events (2)
- · I (S)
- · Z (S)
1910.1028 I01 I
- Issued
- Oct 9, 1997
- Abate by
- Nov 26, 1997
- Penalty
- Initial $300 · Current $120 Reduced
0320
Recent events (2)
- · I (S) $120.00
- · Z (S) $300.00
1910.1028 J03 I
- Issued
- Oct 9, 1997
- Abate by
- Nov 26, 1997
Recent events (2)
- · I (S)
- · Z (S)
1910.106 E06 I
- Issued
- Oct 9, 1997
- Abate by
- Nov 26, 1997
Recent events (2)
- · I (O)
- · Z (O)
1910.1200 E01
- Issued
- Oct 9, 1997
- Abate by
- Nov 26, 1997
901013400320
Recent events (2)
- · I (O)
- · Z (O)
1910.1200 G08
- Issued
- Oct 9, 1997
- Abate by
- Nov 11, 1997
9010
More inspections at Tank Life Specialist
View Tank Life Specialist's full OSHA safety record →
More inspections in this industry (NAICS 000000)
More inspections in WI
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 122475445.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.