LITTLE ROCK, AR ·
OSHA Inspection: GIL CAVER, DDS
Complaint inspection · Health discipline
At a glance
On , OSHA opened a complaint health inspection of GIL CAVER, DDS in 5307 KAVANAUGH, LITTLE ROCK, AR 72207 (NAICS 000000). OSHA activity number 123375297.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- GIL CAVER, DDS
- Site address
- 5307 KAVANAUGH
- City
- LITTLE ROCK
- State
- AR
- ZIP
- 72207
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Health
- Advance notice
- No
- Union status
- Non-union (N)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Data loaded
Establishment context
- NAICS code
- 000000
- SIC code (legacy)
- 8021
- Employees
- 5
- Ownership type
- Private (A)
Citations
8 citations on file for this inspection.
5(a)(1)
- Issued
- Jan 30, 1995
- Abate by
- Jan 31, 1996
- Penalty
- Initial $750 · Current $100 Reduced
1953
General-duty citation text
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The %% employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to: On site, employees performing or assisting in dental procedures where nitrous oxide was administered to patients as an anesthetic gas, were exposed to the waste nitrous oxide gas in levels exceeding the recommended exposure level (REL) of 25 parts per million (PPM) as an 8-hour time weighted average (TWA). The REL was established by the National Institute of Occupational Safety and Health (NIOSH), U.S. Department of Health and Human Services to protect employees from the harmful health effects of nitrous oxide including reduced fertility, spontaneous abortions, and neurologic, renal, and liver disease. Air monitoring conducted on 10-31-94 indicated employee exposure to airborne nitrous oxide as listed in the following table: Job TitleTotal Sample TimeActual Exposure Level8-Hour TWA in Minutes(PPM)(PPM) Dentist59 483.00 59.4 Dental Assistant58896.00108.3 Feasible and effective abatement methods can include, but are not limited to the following: Engineering Controls: 1.Perform additional monitoring of nitrous oxide levels, including monitoring of air from the workers personal breathing zone. 2.Leak test all equipment, including cylinder connections, distribution and recovery (scavenger) lines, seals, etc. Exposure to nitrous oxide and repeated sterilization can degrade rubber and plastic components. 3.If not completed, install a nitrous waste gas scavenger system. 4.Supply scavenging mask in a variety of sizes so that the mask fits correctly over the patients face, forming a comfortable and secure fit. 5.Make sure that the scavenging system exhaust rates (flow rates) are approximately 45 liters per minute (L/min) to minimize nitrous leakage. Monitor the flow rate with a flowmeter that is:-Validated to measure air flow within 5of actual air flow, -Permanently connected to the scavenging system vacuum line, and -Positioned so that it is always visible to the operator. 6.Vent nitrous oxide from all scavenging pumps to the outside of the building away from any fresh air intakes, windows, or walkways. 7.Increase the air flow into the room(s) or increase the percentage of outside air to allow for more air mixing and further dilution of the anesthetic gas. Maintain a balanced air supply and exhaust system so that nitrous does not contaminate adjacent areas. 8.Consider the use of supplementary local ventilation (such as a vent hood) in conjunction with a scavenging system to reduce nitrous exposures in the operatory. The effectiveness of this type of ventilation may depend on its location with respect to the patient and the airflow rates. Do not work between the patient and the exhaust duct, where contaminated air would be drawn through the workers breathing zone. Work Practice Controls: 1.Do not turn on the nitrous delivery system until: -The vacuum system scavenging unit is operating at a flow rate of at least 45 L/min, and -The scavenging mask is securely over the patient's nose or face. 2.Assure the mask is fastened according to the manufacturers instructions to reduce leakage. 3.Flush the system of nitrous after the procedure by administering oxygen to the patient through the anesthetic equipment for at least 5 minutes before disconnecting the gas delivery system. 4.Encourage the patient to minimize talking and mouth-breathing during dental procedures. Respiratory Protection:If levels can not be maintained below 25 parts per million as an 8hour time weighted average, the following controls should be considered: 1.Wear air supplied respirators. If respirators are used, the employer must comply with the provisions of the OSHA Respiratory Protection Standard, 29CFR 1910.134. Abatement Disclaimers: 1.The employer is not limited to the abatement methods suggested by OSHA. 2.The abatement methods explained are general, and may not be effective in all cases. 3.The employer is responsible to selecting and carrying out an appropriate abatement method.
Recent events (3)
- · P (S) $100.00
- · I (S) $100.00
- · Z (S) $750.00
1910.1030 C01 IIB
- Issued
- Jan 30, 1995
- Abate by
- Feb 24, 1995
- Penalty
- Initial $450 · Current $120 Reduced
Recent events (2)
- · I (S) $120.00
- · Z (S) $450.00
1910.1030 C02 IC
- Issued
- Jan 30, 1995
- Abate by
- Feb 24, 1995
1910.1030 C01 IIC
- Issued
- Jan 30, 1995
- Abate by
- Feb 24, 1995
1910.1030 G02 I
- Issued
- Jan 30, 1995
- Abate by
- Feb 24, 1995
- Penalty
- Initial $750 · Current $263 Reduced
Recent events (2)
- · I (S) $262.50
- · Z (S) $750.00
1910.1200 H
- Issued
- Jan 30, 1995
- Abate by
- Feb 24, 1995
- Penalty
- Initial $1,050 · Current $368 Reduced
Recent events (2)
- · I (S) $367.50
- · Z (S) $1050.00
1910.1030 F02 IV
- Issued
- Jan 30, 1995
- Abate by
- Feb 24, 1995
1910.1030 C01 IV
- Issued
- Jan 30, 1995
- Abate by
- Feb 24, 1995