OSHA Inspection: PENNZOIL-QUAKER STATE CO. SHREVEPORT REFINERY

Accident-driven inspection · Safety discipline

On , OSHA opened an accident-driven safety inspection of PENNZOIL-QUAKER STATE CO. SHREVEPORT REFINERY in 3333 MIDWAY AVE, SHREVEPORT, LA 71109 (NAICS 324110). OSHA activity number 123449480.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Pennzoil-Quaker State CO. Shreveport Refinery for free Get an email when a new federal OSHA severe-injury report for Pennzoil-Quaker State CO. Shreveport Refinery is published. One employer, no account, unsubscribe in one click.
Site address
3333 MIDWAY AVE
City
SHREVEPORT
State
LA
ZIP
71109
Mailing
PO BOX 3099, SHREVEPORT, LA 71113
Inspection type
Accident-driven (A)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
Union (Y)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
324110
SIC code (legacy)
2911
Employees
329
Ownership type
Private (A)
Industry flags
Manufacturing safety.

5 citations on file for this inspection.

5(a)(1)

Unclassified Gravity 10 1 instance 329 exposed
Issued
Jul 17, 2000
Abate by
Jul 18, 2002
Penalty
Initial $151,000 · Current $151,000
Section 5(a)(1) of the Occupational Safety and Health Act of 1970:  The
employer did not
furnish to each of his employees a place of employment which was free from
recognized hazards
that were causing or likely to cause death or serious physical harm to
employees in that
employees were exposed to the following condition(s):
Pennzoil-Quaker State Company Shreveport Refinery, Naphtha Unifiner,
Shreveport LA. For
the period of time up to and including 18 Jan 00, Heat exchangers in the
Naphtha Unifiner
(specifically the 55-EX-02B exchanger) were continually inspected using
the inspection criteria
set forth in API 510. Corrosion problems have occurred previously. Failure
to modify the
inspection procedures in light of historical experience exposed employees
to the hazards related
to failure of the exchanger.
Among other methods, one feasible and acceptable abatement method to
correct
this hazard is
to conduct ultrasonic transmission (UT) inspections of the heat exchangers
in a way that targeted
the expected area of highest concern regarding corrosion and/or vessel
failure.

1910.119 C01

Unclassified Gravity 10 2 instances 329 exposed
Issued
Jul 17, 2000
Abate by
Jul 18, 2001

1910.119 C02

Unclassified Gravity 10 1 instance 329 exposed
Issued
Jul 17, 2000
Abate by
Jul 18, 2001

1910.119 E03 I

Unclassified Gravity 10 1 instance 329 exposed
Issued
Jul 17, 2000
Abate by
Oct 20, 2000

1910.119 E03 II

Unclassified Gravity 10 1 instance 329 exposed
Issued
Jul 17, 2000
Abate by
Oct 20, 2000

View Pennzoil-Quaker State CO. Shreveport Refinery's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 123449480.