VESTAL, NY —
OSHA Inspection: VESTAL TN HIGHWAY DEPT
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of VESTAL TN HIGHWAY DEPT in 1801 GLENWOOD RD, VESTAL, NY 13850 (NAICS 000000). OSHA activity number 124495334.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- VESTAL TN HIGHWAY DEPT
- Site address
- 1801 GLENWOOD RD
- City
- VESTAL
- State
- NY
- ZIP
- 13850
- Mailing
- 605 VESTAL PKWY WEST, VESTAL, NY 13850
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- Y
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 000000
- SIC code (legacy)
- 1611
- Employees
- 37
- Ownership type
- B
Citations
12 citations on file for this inspection.
3A0001
- Issued
- Dec 1, 1998
- Abate by
- May 27, 1999
General-duty citation text
Section 27-a(3)(i): The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or were likely to cause death or serious physical harm to employees in that employees were exposed to the hazard of being struck by a falling vehicle, in the event of hydraulic failure of the twin post, Rotary Lift, hydraulic vehicle lift, Model #AF70E, Serial # n/a, while servicing vehicles. Among other methods, one feasible and acceptable abatement method to correct this hazard is to equip the lift with a mechanical device to hold the lift in the fully extended position as recommended by the American National Standards Institute and the Automobile Lift Institute in the industry consensus standard ANSI/ALI B153.1: "Safety Requirements for the Construction, Care and Use of Automobile Lifts". The device should have a strength factor of not less than three, based on the rated load capacity of the lift: a) The two twin post, Rotary Lift, hydraulic vehicle lifts in the highway garage are not equipped with positive stops when the posts are fully extended - crushing hazard.
1910.108 G06 I
- Issued
- Dec 1, 1998
- Abate by
- Jan 5, 1999
1910.212 A03 II
- Issued
- Dec 1, 1998
- Abate by
- Jan 5, 1999
1910.243 C03
- Issued
- Dec 1, 1998
- Abate by
- Dec 18, 1998
1910.253 B04 III
- Issued
- Dec 1, 1998
- Abate by
- Dec 28, 1998
1910.334 A02 II
- Issued
- Dec 1, 1998
- Abate by
- Dec 28, 1998
1926.602 A09 I
- Issued
- Dec 1, 1998
- Abate by
- Jan 20, 1999
1910.145 C03
- Issued
- Dec 1, 1998
- Abate by
- Jan 20, 1999
1910.147 C06 II
- Issued
- Dec 1, 1998
- Abate by
- Jan 20, 1999
1910.215 A04
- Issued
- Dec 1, 1998
- Abate by
- Dec 18, 1998
1910.304 F04
- Issued
- Dec 1, 1998
- Abate by
- Jan 20, 1999
1910.1200 F05 I
- Issued
- Dec 1, 1998
- Abate by
- Dec 28, 1998
More inspections at Vestal TN Highway Dept
View Vestal TN Highway Dept's full OSHA safety record →
More inspections in this industry (NAICS 000000)
More inspections in NY
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 124495334.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.