ARLINGTON, VA —
OSHA Inspection: THE STRONG COMPANIES, INC.
Accident-driven inspection · Safety discipline
At a glance
On , OSHA opened an accident-driven safety inspection of THE STRONG COMPANIES, INC. in 359 IRVING STREET, ARLINGTON, VA 22201 (NAICS 000000). OSHA activity number 125448357.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- THE STRONG COMPANIES, INC.
- Site address
- 359 IRVING STREET
- City
- ARLINGTON
- State
- VA
- ZIP
- 22201
- Mailing
- 13850 BARNSFIELD ROAD, CHANTILLY, VA 22071
What kind of inspection was it?
- Inspection type
- Accident-driven (A)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- N
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 000000
- SIC code (legacy)
- 1623
- Employees
- 7
- Ownership type
- A
- Industry flags
- Construction safety.
Citations
3 citations on file for this inspection.
1926.21 B02
- Issued
- Apr 27, 1998
- Abate by
- May 1, 1998
- Penalty
- Initial $7,000 · Current $7,000
Recent events (2)
- — Y (S) $7000.00
- — Z (S) $7000.00
1926.652 A01
- Issued
- Apr 27, 1998
- Abate by
- May 1, 1998
- Penalty
- Initial $1,750 · Current $1,750
Recent events (2)
- — Y (S) $1750.00
- — Z (S) $1750.00
510001 A
- Issued
- Apr 27, 1998
- Abate by
- May 1, 1998
- Penalty
- Initial $70,000 · Current $70,000
General-duty citation text
Virginia Code 40.1-51.1(a): The employer did not furnish employment, and a place of employment, which were free from recognized hazards that were causing, or likely to cause, death or serious physical harm to employee(s) in that employee(s) were exposed to the impact hazard of a large volume of compressed air that was contained under high pressure. On 11/04/97, in front of 359 Irving Street, Arlington, Virginia, a pressure test was conducted on a 12" diameter steel natural gas (dry) pipeline, for which the end cap was held in place by a Dresser #38 coupling, and with an employee monitoring the pressure increase from a position within an unprotected trench. The employer failed to adhere to the provisions of the Washington Gas Company, Inc., Distribution Department's Operating Instructions, which prohibits the use of couplings when pressure testing pipelines with a diameter in excess of 10", and that an employee was allowed to remain in the proximity of the "deadhead" (end cap) while the pressure test was in process. One feasible and acceptable method to correct these hazards would have been to weld the "deadhead" (end cap) in place, and remove the employee from the trench, away from the area of danger.
Recent events (2)
- — Y (W) $70000.00
- — Z (W) $70000.00