Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: THE STRONG COMPANIES, INC.

Accident-driven inspection · Safety discipline

On , OSHA opened an accident-driven safety inspection of THE STRONG COMPANIES, INC. in 359 IRVING STREET, ARLINGTON, VA 22201 (NAICS 000000). OSHA activity number 125448357.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch The Strong Companies, INC. — free Get an email when a new federal OSHA severe-injury report for The Strong Companies, INC. is published. One employer, no account, unsubscribe in one click.
Site address
359 IRVING STREET
City
ARLINGTON
State
VA
ZIP
22201
Mailing
13850 BARNSFIELD ROAD, CHANTILLY, VA 22071
Inspection type
Accident-driven (A)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
N
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
000000
SIC code (legacy)
1623
Employees
7
Ownership type
A
Industry flags
Construction safety.

3 citations on file for this inspection.

1926.21 B02

Deleted Serious Gravity 10 1 instance 1 exposed
Issued
Apr 27, 1998
Abate by
May 1, 1998
Penalty
Initial $7,000 · Current $7,000
Recent events (2)
  • — Y (S) $7000.00
  • — Z (S) $7000.00

1926.652 A01

Deleted Serious Gravity 03 1 instance 1 exposed
Issued
Apr 27, 1998
Abate by
May 1, 1998
Penalty
Initial $1,750 · Current $1,750
Recent events (2)
  • — Y (S) $1750.00
  • — Z (S) $1750.00

510001 A

Deleted Willful Gravity 10 1 instance 1 exposed
Issued
Apr 27, 1998
Abate by
May 1, 1998
Penalty
Initial $70,000 · Current $70,000
Virginia Code  40.1-51.1(a): The employer did not furnish employment, and a
place of employment, which were free from recognized hazards that were
causing,
or likely to cause, death or serious physical harm to employee(s) in that
employee(s) were exposed to the impact hazard of a large volume of
compressed air
that was contained under high pressure.  On 11/04/97, in front of 359
Irving
Street, Arlington, Virginia, a pressure test was conducted on a 12"
diameter
steel natural gas (dry) pipeline, for which the end cap was held in place
by a
Dresser #38 coupling, and with an employee monitoring the pressure
increase from
a position within an unprotected trench.  The employer failed to adhere to
the
provisions of the Washington Gas Company, Inc., Distribution Department's
Operating Instructions, which prohibits the use of couplings when pressure
testing pipelines with a diameter in excess of 10", and that an employee
was
allowed to remain in the proximity of the "deadhead" (end cap) while the
pressure
test was in process.
One feasible and acceptable method to correct these hazards would have
been to
weld the "deadhead" (end cap) in place, and remove the employee from the
trench,
away from the area of danger.
Recent events (2)
  • — Y (W) $70000.00
  • — Z (W) $70000.00

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 125448357.