Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,191,288Inspections Most recent open 2026-07-24 Last loaded 2026-07-29

OSHA Inspection: EMPRESAS RIVERA SIACA INC

Unprogrammed Related inspection · Safety discipline

On , OSHA opened an unprogrammed Related safety inspection of EMPRESAS RIVERA SIACA INC in CALLE TNTE CESAR GONZALEZ URB TRES MONJITAS, SAN JUAN, PR 00919 (NAICS 000000). OSHA activity number 126960772.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Empresas Rivera Siaca INC — free Get an email when a new federal OSHA severe-injury report for Empresas Rivera Siaca INC is published. One employer, no account, unsubscribe in one click.
Site address
CALLE TNTE CESAR GONZALEZ URB TRES MONJITAS
City
SAN JUAN
State
PR
ZIP
00919
Mailing
PO BOX 192647, SAN JUAN, PR 00919
Inspection type
Unprogrammed Related (G)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
N
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
000000
SIC code (legacy)
6512
Employees
8
Ownership type
A

2 citations on file for this inspection.

6A0001

Deleted Serious 1 instance 3 exposed
Issued
Oct 7, 1997
Abate by
Oct 10, 1997
Penalty
Initial $450 · Current $450
Section 6(a) of the Puerto Rico Occupational Safety and Health Act:  The
employer
did not furnish employment and a place of employment which were free from
recognized hazards that were causing or likely to cause death or physical
harm
to employees in that employees were exposed to:
Seccion 6(a) de la Ley de Seguridad y Salud en el Trabajo de Puerto Rico:
El
patrono no proveyo empleo y un sitio de empleo libre de riesgos
reconocidos que
esten causando o que puedan causar muerte o dano fisico a los empleados,
por
cuanto empleados estaban expuestos a:
At the establishment; Vocational Funds Section: Over 8 feet high (9 feet
aproximately), there were electric cords, UF cables, burned.  Employees
heared low explotions, and observed sparks between the acoustic plates.
Hazard:  Fire.
Among other methods, one feasible and acceptable abatement method to
correct this electrical hazard is, to removed the barned cords and
insulated the others.
En el establecimiento; Seccion de Fondos vocacionales:  Sobre los 8 pies
de altura (9 pies aproximadamente), hay cables electricos UF, quemados.
Los empleados escuchaban pequenas esplosiones y observaban chispas por
entre las planchas del acustico.
Riesgo:  Fuego.
Entre otros metodos, un metodo aceptable de correccion de este riesgo
electrico seria; remover los cables quemados y proteger aislando los otros
cables.o
Recent events (2)
  • — I (S) $450.00
  • — Z (S) $450.00

1910.22 A01

Serious 1 instance 3 exposed
Issued
Oct 7, 1997
Abate by
Oct 14, 1997
Penalty
Initial $450 · Current $225 Reduced
Recent events (2)
  • — I (S) $225.00
  • — Z (S) $450.00

View Empresas Rivera Siaca INC's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 126960772.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.