Sewickley, PA ·
OSHA Inspection: PENN ERECTION CO
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of PENN ERECTION CO in NURSING HOME MERRIMAN RD, Sewickley, PA 15143 (NAICS 000000). OSHA activity number 12787198.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- PENN ERECTION CO
- Site address
- NURSING HOME MERRIMAN RD
- City
- Sewickley
- State
- PA
- ZIP
- 15143
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Union status
- Union (A)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Data loaded
Establishment context
- NAICS code
- 000000
- SIC code (legacy)
- 1791
- Employees
- 15
- Industry flags
- Construction safety.
Citations
1 citation on file for this inspection.
1904.2 A
- Issued
- Jul 15, 1983
- Abate by
- Jul 19, 1983
More inspections at Penn Erection CO
View Penn Erection CO's full OSHA safety record →
More inspections in this industry (NAICS 000000)
More inspections in PA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 12787198.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.