Beaver, PA ·
OSHA Inspection: RAWDING ELECTRIC SERVICE CO
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of RAWDING ELECTRIC SERVICE CO in 699 5TH & INSURANCE ST, Beaver, PA 15009 (NAICS 000000). OSHA activity number 12868337.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- RAWDING ELECTRIC SERVICE CO
- Site address
- 699 5TH & INSURANCE ST
- City
- Beaver
- State
- PA
- ZIP
- 15009
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Union status
- Non-union (B)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Data loaded
Establishment context
- NAICS code
- 000000
- SIC code (legacy)
- 1731
- Employees
- 5
- Industry flags
- Construction safety.
Citations
2 citations on file for this inspection.
1926.25 A
- Issued
- Jan 16, 1974
- Abate by
- Jan 18, 1974
1926.401 J03
- Issued
- Jan 16, 1974
- Abate by
- Jan 18, 1974
More inspections in this industry (NAICS 000000)
More inspections in PA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 12868337.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.