PHILADELPHIA, PA —
OSHA Inspection: GLASS MASTERS
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of GLASS MASTERS in 3 N. COLUMBUS BLVD., PHILADELPHIA, PA 19106 (NAICS 000000). OSHA activity number 17709395.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- GLASS MASTERS
- Site address
- 3 N. COLUMBUS BLVD.
- City
- PHILADELPHIA
- State
- PA
- ZIP
- 19106
- Mailing
- 591 1/2 ALCOTT ST., PHILADELPHIA, PA 19120
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- N
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Data loaded
Establishment context
- NAICS code
- 000000
- SIC code (legacy)
- 7349
- Employees
- 4
- Ownership type
- A
- Industry flags
- Manufacturing safety.
Citations
3 citations on file for this inspection.
5(a)(1)
- Issued
- Jul 10, 1995
- Abate by
- Jul 13, 1995
- Penalty
- Initial $1,500 · Current $500 Reduced
General-duty citation text
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to fall hazards of approximately 40 feet while cleaning windows: a) Pier 3 Condominium, 3 N. Columbus Blvd., Philadelphia, PA 19106 - an employee was observed cleaning windows while suspended from a boatswains chair using a "rack" system controlled descent device that was attached to a "Fitch" portable boom that was not properly rigged. The employees' safety line was not independently secured to an anchoring system also the "Fitch" boom system was not properly secured to an anchoring system in that there was approximately 15 feet of slack in the tieback line. The required counterweight safety factor of 4 to 1 also was not met. Observed 06/15/95. Some feasible and useful means of abatement of these issues would be: 1) To independently secure the safety line to an anchoring point capable of supporting 5000 lbs. 2) To properly secure the boom system ensuring that there is no slack in the tieback line and properly secured to an anchoring point capable of supporting 5000 lbs. 3) To increase the counterweight to ensure that there is always a 4 to 1 safety factor between the suspended weight and the counterweight.
Recent events (2)
- — I (S) $500.00
- — Z (S) $1500.00
1910.132 A
- Issued
- Jul 10, 1995
- Abate by
- Jul 13, 1995
- Penalty
- Initial $1,500 · Current $500 Reduced
Recent events (2)
- — I (S) $500.00
- — Z (S) $1500.00
1910.132 D01
- Issued
- Jul 10, 1995
- Abate by
- Jul 13, 1995
More inspections at Glass Masters
View Glass Masters's full OSHA safety record →
More inspections in this industry (NAICS 000000)
More inspections in PA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 17709395.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.