Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,197,124Inspections Most recent open 2026-08-25 Last loaded 2026-08-28

OSHA Inspection: NASSAU CHEMICAL CORPORATION

Referral inspection · Health discipline

On , OSHA opened a referral health inspection of NASSAU CHEMICAL CORPORATION in 1008 WHITEHEAD ROAD EXT., TRENTON, NJ 08638 (NAICS 000000). OSHA activity number 17780636.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Nassau Chemical Corporation for free Get an email when a new federal OSHA severe-injury report for Nassau Chemical Corporation is published. One employer, no account, unsubscribe in one click.
Site address
1008 WHITEHEAD ROAD EXT.
City
TRENTON
State
NJ
ZIP
08638
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
Non-union (B)
Opened
Closing conference
Case closed
Data loaded
NAICS code
000000
SIC code (legacy)
2821
Employees
90
Ownership type
Private (A)

1 citation on file for this inspection.

5(a)(1)

Serious 1 instance 10 exposed
Issued
Dec 31, 1986
Abate by
Jan 3, 1987
Penalty
Initial $150 · Current $150
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The
employer did not furnish employment and a place of employment which were
free from recognized hazards that were causing or likely to cause death
or serious physical harm to employees in that employees were exposed to:
toxic thermal decomposition products (such as hydrogen bromide, which
may cause acute lung damage) as a result of the overheating of a batch
of Wyfire R H-EA75 in the Banbury Mixer, on or about 8/27/86.
Among other methods, one feasible and acceptable abatement method to
correct the hazard is to implement:
1) The use of automatic controls (with or without alarms) designed to
drop the batch from the mixer at a predetermined temperature and/or
time selected to ensure that the batch will remain stable.
2) The incremental addition of raw materials, especially antimony
trioxide, to slow the temperature rise of the batch and allow
dissipation of heat.
3) The installation of remote activated water spray nozzles or other
means to quench/extinguish overheated batches in the event of failure
of controls.
4) Redundant instrumentation for critical parameters, such as
temperatures.

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 17780636.