OSHA Inspection: ULTRA ELECTRICAL CONTRACTORS INC.

Unprogrammed Related inspection · Safety discipline

On , OSHA opened an unprogrammed Related safety inspection of ULTRA ELECTRICAL CONTRACTORS INC. in 6400 RIVER ROAD, WEST NEW YORK, NJ 07093 (NAICS 000000). OSHA activity number 17850496.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Ultra Electrical Contractors INC. — free Get an email when a new federal OSHA severe-injury report for Ultra Electrical Contractors INC. is published. One employer, no account, unsubscribe in one click.
Site address
6400 RIVER ROAD
City
WEST NEW YORK
State
NJ
ZIP
07093
Mailing
708 OPATUT COURT, TOMS RIVER, NJ 08703
Inspection type
Unprogrammed Related (G)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
Y
Opened
Closing conference
Case closed
Data loaded
NAICS code
000000
SIC code (legacy)
1731
Employees
6
Ownership type
A

8 citations on file for this inspection.

5(a)(1)

Serious Gravity 03 1 instance 2 exposed
Issued
Sep 24, 1991
Abate by
Sep 27, 1991
Penalty
Initial $375 · Current $188 Reduced
Section 5(a)(1) of the Occupational Safety and Health Act of 1970:  The
employer did not furnish employment and a place of employment which
were free from recognized hazards that were causing or likely to cause
death or serious physical harm to employees in that employees were
exposed to hazard of being caught in the rotating parts of the machine:
a) Generator Building
Employees were using a Rigid 300 electric pipe threader, serial number
772032, which did not have a constant pressure control switch as
required by the American National Standards Institute B208.1-1982,
Section 4.4.  Among other methods, one feasible and acceptable
abatement method to correct this hazard is to install a constant
pressure foot control switch.
Violation observed on or about 5/17/91
Recent events (2)
  • — I (S) $188.00
  • — Z (S) $375.00

1926.500 D01

Serious Gravity 03 1 instance 6 exposed
Issued
Sep 24, 1991
Abate by
Sep 27, 1991
Penalty
Initial $375 · Current $187 Reduced
Recent events (2)
  • — I (S) $187.00
  • — Z (S) $375.00

1926.701 B

Serious Gravity 03 1 instance 6 exposed
Issued
Sep 24, 1991
Abate by
Sep 27, 1991
Penalty
Initial $375 · Current $188 Reduced
Recent events (2)
  • — I (S) $188.00
  • — Z (S) $375.00

1926.1052 C01

Serious Gravity 01 1 instance 2 exposed
Issued
Sep 24, 1991
Abate by
Sep 27, 1991
Penalty
Initial $375 · Current $187 Reduced
Recent events (2)
  • — I (S) $187.00
  • — Z (S) $375.00

1903.2 A01

Other-than-serious Gravity 01 1 instance 6 exposed
Issued
Sep 24, 1991
Abate by
Sep 27, 1991
Penalty
Initial $150 · Current $75 Reduced
Recent events (2)
  • — I (O) $75.00
  • — Z (O) $150.00

1926.403 B02

Other-than-serious Gravity 01 1 instance 2 exposed
Issued
Sep 24, 1991
Abate by
Sep 27, 1991

1926.405 B02

Other-than-serious Gravity 01 1 instance 2 exposed
Issued
Sep 24, 1991
Abate by
Sep 27, 1991

1926.1052 A01

Other-than-serious Gravity 01 1 instance 6 exposed
Issued
Sep 24, 1991
Abate by
Sep 28, 1991

View Ultra Electrical Contractors INC.'s full OSHA safety record →