WOODLAND, MS —
OSHA Inspection: R & R FURNITURE, INC.
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of R & R FURNITURE, INC. in CHICKASAW ROAD #66, WOODLAND, MS 39669 (NAICS 000000). OSHA activity number 18131573.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- R & R FURNITURE, INC.
- Site address
- CHICKASAW ROAD #66
- City
- WOODLAND
- State
- MS
- ZIP
- 39669
- Mailing
- ROUTE 1 BOX 8-R, WOODLAND, MS 39776
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- N
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Data loaded
Establishment context
- NAICS code
- 000000
- SIC code (legacy)
- 2521
- Employees
- 24
- Ownership type
- A
- Industry flags
- Manufacturing safety.
Citations
9 citations on file for this inspection.
5(a)(1)
- Issued
- Aug 18, 1994
- Abate by
- Oct 20, 1994
- Penalty
- Initial $450 · Current $340 Reduced
General-duty citation text
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to: (a)Hazard of being struck by shattered P. V. C. Pipe throughout plant which was installed above ground and was not constructed of or encased in shatter residant material. PVC Plastic Pipe with ASTM designation D 1785, Schedules 40, 80, and 120 are pressured rated for water at 23 C. Among other methods one feasible and acceptable abatement method to correct this hazard is to encase the P. V. C. pipe with shatter resistant material in above rough locations in above ground locations.
Recent events (2)
- — I (S) $340.00
- — Z (S) $450.00
1910.22 B01
- Issued
- Aug 18, 1994
- Abate by
- Sep 7, 1994
- Penalty
- Initial $450 · Current $340 Reduced
Recent events (2)
- — I (S) $340.00
- — Z (S) $450.00
1910.36 B04
- Issued
- Aug 18, 1994
- Abate by
- Sep 7, 1994
1910.133 A01
- Issued
- Aug 18, 1994
- Abate by
- Sep 7, 1994
- Penalty
- Initial $1,050 · Current $780 Reduced
Recent events (2)
- — I (S) $780.00
- — Z (S) $1050.00
1910.138 A
- Issued
- Aug 18, 1994
- Abate by
- Sep 7, 1994
- Penalty
- Initial $600 · Current $450 Reduced
Recent events (2)
- — I (S) $450.00
- — Z (S) $600.00
1910.212 A03 II
- Issued
- Aug 18, 1994
- Abate by
- Sep 14, 1994
- Penalty
- Initial $450 · Current $340 Reduced
Recent events (2)
- — I (S) $340.00
- — Z (S) $450.00
1910.213 C01
- Issued
- Aug 18, 1994
- Abate by
- Sep 7, 1994
- Penalty
- Initial $600 · Current $450 Reduced
Recent events (2)
- — I (S) $450.00
- — Z (S) $600.00
1910.22 A01
- Issued
- Aug 18, 1994
- Abate by
- Sep 7, 1994
1910.37 Q01
- Issued
- Aug 18, 1994
- Abate by
- Sep 7, 1994
More inspections in this industry (NAICS 000000)
More inspections in MS
Source