DUTCH HARBOR, AK —
OSHA Inspection: HIGHLAND LIGHT SEAFOODS LLC
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of HIGHLAND LIGHT SEAFOODS LLC in M/V WESTWARD WIND-DUTCH HARBOR, DUTCH HARBOR, AK 99603 (NAICS 000000). OSHA activity number 18166983.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- HIGHLAND LIGHT SEAFOODS LLC
- Site address
- M/V WESTWARD WIND-DUTCH HARBOR
- City
- DUTCH HARBOR
- State
- AK
- ZIP
- 99603
- Mailing
- 3600 15TH AVENUE W. SUITE 300, SEATTLE, WA 98119
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- N
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 000000
- SIC code (legacy)
- 2092
- Employees
- 21
- Ownership type
- A
- Industry flags
- Maritime safety.
Citations
1 citation on file for this inspection.
5(a)(1)
- Issued
- Dec 20, 1999
- Abate by
- Jan 10, 2000
- Penalty
- Initial $1,500 · Current $1,500
General-duty citation text
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to: (a)C/P Westward Wind: In the All-Hands Bathroom is a receptacle less than three feet from the sink that was not GFCI protected. This condition exposed employees to possible electrical shock/burns or electrocution when an event of an accidental contact. Among other methods, one feasible and acceptable abatement method to correct this hazard would be to install a GFCI receptacle or GFCI breaker. (b)C/P Westward Wind: In the Galley are five receptacle near the sink less than three feet from the sink that was not GFCI protected. This condition exposed employees to possible electrical shock/burn or electrocution when an event of an accidental contact. Among other methods, one feasible and acceptable abatement method to correct this hazard would be to install a GFCI receptacle or GFCI breaker. (c)C/P Westward Wind: In the Factory Fore Peak is a Setpoint Temperature Control model SP-32 with a replacement power cord and no strain relief. This condition exposed employees to live electrical conductors with the possibility of electrical shock/burn or electrocution when an event of an accidental contact. Among other methods, one feasible and acceptable abatement method to correct this hazard would be to hard wire the system and install a strain relief. (d)C/P Westward Wind: In the Dry Storage area (behind the Galley) were 2' fluorescent lighting less than 7' from the deck with covers missing. This condition exposed employees to possible electrical shock/burn or electrocution when an event of an accidental contact. Among other methods, one feasible and acceptable abatement method to correct this hazard would be install covers.
More inspections at Highland Light Seafoods LLC
View Highland Light Seafoods LLC's full OSHA safety record →
More inspections in this industry (NAICS 000000)
More inspections in AK
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 18166983.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.