WILKES-BARRE, PA —
OSHA Inspection: ABEL ELECTRIC
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of ABEL ELECTRIC in WYOMING VALLEY SANITARY AUTH/1000 WILKES-BARRE ST, WILKES-BARRE, PA 18701 (NAICS 000000). OSHA activity number 18226100.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- ABEL ELECTRIC
- Site address
- WYOMING VALLEY SANITARY AUTH/1000 WILKES-BARRE ST
- City
- WILKES-BARRE
- State
- PA
- ZIP
- 18701
- Mailing
- P. O. BOX 794, WYALUSING, PA 18853
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Data loaded
Establishment context
- NAICS code
- 000000
- SIC code (legacy)
- 1731
- Employees
- 5
- Ownership type
- A
- Industry flags
- Construction safety.
Citations
10 citations on file for this inspection.
5(a)(1)
- Issued
- Feb 7, 1991
- Abate by
- Feb 12, 1991
- Penalty
- Initial $560 · Current $280 Reduced
General-duty citation text
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to potential toxic and oxygen deficient atmosphere hazards while working in a confined space: A) Employees working in pumping stations of the Wyoming Valley Sanitary Authority, Nos. 16, 13, 15, and others were exposed to potential toxic and oxygen deficient atmosphere hazards in that no atmosphere testing was done prior to entry, no emergency rescue equipment was available, December 27,1990. AMONG OTHER METHODS, ONE FEASIBLE AND ACCEPTABLE METHOD TO CORRECT THIS HAZARD IS THE ESTABLISHMENT OF A CONFINED SPACE ENTRY PROGRAM CONSISTING OF AT LEAST THE FOLLOWING: 1) Implementation of confined space entry permit procedures which lists the precautions to be taken, the following "checklist" or precautions should be included on the entry permit: hazard(s) identified; testing and emergency procedures established; electrical equipment de-energized and locked-out; contaminants diluted by purging or ventilation; lifelines and safety belts utilized, and rescue equipment in place and tested. 2) Conduct atmosphere monitoring and testing prior to entry and during the time period that work is being performed in the confined space. Testing shall be for oxygen content; toxic substance concentrations, and flammable gases. 3) Attach a safety belt and lifeline to the employee entering the confined space. 4) Provide a trained standby employee outside of the confined space to maintain communication with the confined space workers, unobstructed lifelines, and procedures for obtaining immediate help in the event of an emergency. Rescuers should be instructed and drilled in rescue procedures. Rescuers should be informed not to enter the confined area unless others are standing by in the event that additional help is required. The rescuer should be equipped with proper personal protective equipment including a lifeline and safety belt. 5) Instruct employees as to the nature of the hazards involved and the necessary precautions to be taken in regard to entry into the confined space. Employees should be trained with emphasis on the hazards associated with their work, the proper entry procedures to be followed and the required personal protective equipment needed when entry is made. Rescuers should be trained in artificial respiration techniques and basic first-aid procedures. 6) Provide sufficient exhaust ventilation to keep the concentration of toxic substances in the confined space to within permissable exposure limits and ensure that ventilation exhaust ducts discharge clear of working areas. 7) Provide readily available emergency standby equipment consisting of a safety line and/or harness of sufficient length and where the internal atmosphere is oxygen deficient or contains toxic gases, a self-contained breathing apparatus or a supplied-air respirator should be utilized by the employee entering the confined space and one available for rescue. 8) All entrances to confined spaces should be posted: "Danger, confined space, entry by permit only".
Recent events (2)
- — I (S) $280.00
- — Z (S) $560.00
1926.404 B01 I
- Issued
- Feb 7, 1991
- Abate by
- Feb 12, 1991
- Penalty
- Initial $640 · Current $640
1926.404 F06
- Issued
- Feb 7, 1991
- Abate by
- Mar 8, 1991
Recent events (2)
- — I (S)
- — Z (S)
1926.416 A01
- Issued
- Feb 7, 1991
- Abate by
- Mar 8, 1991
- Penalty
- Initial $640 · Current $540 Reduced
Recent events (2)
- — I (S) $540.00
- — Z (S) $640.00
1926.20 B02
- Issued
- Feb 7, 1991
- Abate by
- Feb 12, 1991
1903.2 A01
- Issued
- Feb 7, 1991
- Abate by
- Feb 12, 1991
- Penalty
- Initial $80 · Current $80
1926.50 C
- Issued
- Feb 7, 1991
- Abate by
- Mar 9, 1991
1926.59 E01
- Issued
- Feb 7, 1991
- Abate by
- Apr 9, 1991
Recent events (2)
- — I (O)
- — Z (O)
1926.59 H
- Issued
- Feb 7, 1991
- Abate by
- Apr 9, 1991
Recent events (2)
- — I (O)
- — Z (O)
1926.651 B02
- Issued
- Feb 7, 1991
- Abate by
- Feb 12, 1991
More inspections at Abel Electric
View Abel Electric's full OSHA safety record →
More inspections in this industry (NAICS 000000)
More inspections in PA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 18226100.