YAKE BUENA VISTA, FL —
OSHA Inspection: BUENAVISTA CONSTRUCTION, INC.
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of BUENAVISTA CONSTRUCTION, INC. in TYPHOON LAGOON, 1800 BUENA VISTA DRIVE, YAKE BUENA VISTA, FL 32830 (NAICS 000000). OSHA activity number 18245308.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- BUENAVISTA CONSTRUCTION, INC.
- Site address
- TYPHOON LAGOON, 1800 BUENA VISTA DRIVE
- City
- YAKE BUENA VISTA
- State
- FL
- ZIP
- 32830
- Mailing
- P.O. BOX 10,000, LAKE BUENA VISTA, FL 32830
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- Y
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 000000
- SIC code (legacy)
- 1542
- Employees
- 200
- Ownership type
- A
- Industry flags
- Construction safety.
Citations
7 citations on file for this inspection.
5(a)(1)
- Issued
- Feb 15, 1989
- Abate by
- Feb 18, 1989
- Penalty
- Initial $600 · Current $400 Reduced
General-duty citation text
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to: a) Typhoon Lagoon, Building 5 roof, South side - Two employees were not provided with fall protection while installing the quardrail posts at the edge of a 12' high roof on or about December 29, 1988. Among other methods, one feasible and acceptable abatement method to correct this hazard is to have the exposed employees wear approved safety belts with the lanyard secured to a lifeline.
Recent events (2)
- — I (S) $400.00
- — Z (S) $600.00
1926.102 A01
- Issued
- Feb 15, 1989
- Abate by
- Feb 18, 1989
- Penalty
- Initial $500 · Current $300 Reduced
Recent events (2)
- — I (S) $300.00
- — Z (S) $500.00
1926.152 F03
- Issued
- Feb 15, 1989
- Abate by
- Feb 18, 1989
- Penalty
- Initial $400 · Current $300 Reduced
Recent events (2)
- — I (S) $300.00
- — Z (S) $400.00
1926.403 H
- Issued
- Feb 15, 1989
- Abate by
- Feb 18, 1989
- Penalty
- Initial $400 · Current $300 Reduced
Recent events (2)
- — I (S) $300.00
- — Z (S) $400.00
1926.405 D
- Issued
- Feb 15, 1989
- Abate by
- Feb 18, 1989
- Penalty
- Initial $400 · Current $300 Reduced
Recent events (2)
- — I (S) $300.00
- — Z (S) $400.00
1926.451 A04
- Issued
- Feb 15, 1989
- Abate by
- Feb 18, 1989
- Penalty
- Initial $400 · Current $400
1926.701 F01
- Issued
- Feb 15, 1989
- Abate by
- Feb 22, 1989
More inspections at Buenavista Construction, INC.
View Buenavista Construction, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 000000)
More inspections in FL
Source