PHILADELPHIA, PA ·
OSHA Inspection: M.F. BANK THE RESTORATION CO.
Accident-driven inspection · Health discipline
At a glance
On , OSHA opened an accident-driven health inspection of M.F. BANK THE RESTORATION CO. in 5501 TABOR RD., PHILADELPHIA, PA 19120 (NAICS 000000). OSHA activity number 18252999.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- M.F. BANK THE RESTORATION CO.
- Site address
- 5501 TABOR RD.
- City
- PHILADELPHIA
- State
- PA
- ZIP
- 19120
- Mailing
- 3120 MEDLOCK BRIDGE RD. BLDG. J, NORCROSS, GA 30071
What kind of inspection was it?
- Inspection type
- Accident-driven (A)
- Scope
- Complete (A)
- Discipline
- Health
- Advance notice
- No
- Union status
- Non-union (N)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Data loaded
Establishment context
- NAICS code
- 000000
- SIC code (legacy)
- 1799
- Employees
- 19
- Ownership type
- Private (A)
Citations
6 citations on file for this inspection.
5(a)(1)
- Issued
- Mar 22, 1993
- Abate by
- Apr 5, 1993
- Penalty
- Initial $24,500 · Current $20,000 Reduced
General-duty citation text
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to a toxic and/or asphyxiation hazard while performing a cleaning operation using a halogenated organic solvent inside of a sealed room: a) M.F. Bank - The Restoration Company at Mrs. Pauls Kitchens, Inc., 5501 Tabor Rd, Phila, Pa., Motor Control Center - Two (2) Supervisor/ Technicians, and five (5) Subcontractor skilled laborer were required to perform two (2) separate cleaning operations inside of a sealed room (i.e. confined space) on October 3, 1992. The supervisor/technicians were performing an electrical component cleaning operation utilizing a solution of 90 Freon TF690 and 10isopropyl alcohol, applied with a high powered airless sprayer. The room had no existing mechanical ventilation, the workers wore no respiratory protection, and standard confined space entry precautions were not followed. The workers were exposed to a toxic and/or asphyxiation hazard which may have resulted in death or serious physical harm. Observed 10/6/93 b) M.F. Bank - The Restoration Company at Mrs. Pauls Kitchens, Inc., 5501 Tabor Rd, Phila, Pa., Emergency Lighting Room -Three (3) Supervisor/ Technicians, and six (6) Subcontractor skilled laborer were required to perform two (2) separate cleaning operations inside of a sealed room (i.e. confined space) on October 4, 1992. The supervisor/technicians were performing an electrical component cleaning operation utilizing a solution of 90 Freon TF690 and 10isopropyl alcohol, applied with a high powered airless sprayer. The room had no existing mechanical ventilation, the workers were wearing either no respiratory protection or inappropriate respiratory protection, and standard confined space entry precautions were not followed. The workers were exposed to a toxic and/or asphyxiation hazard which may have resulted in the death one (1) worker and the hospitalization of six (6) others. Observed 10/6/93 ABATEMENT NOTE: Among other methods, one feasible and acceptable abatement method to correct this hazard is to develop and implement a comprehensive confined space entry program, which would include the following elements as a minimum: 1. All personnel assigned to work in confined areas shall be properly trained in safe entry and rescue procedures. The training shall provide a working knowledge and understanding of any and all hazards that may exist. 2. Entry into confined spaces shall be by written entry permit, issued by the responsible supervisor or other qualified person. The permit must include a checklist of precautions to be reviewed prior to entry and document the location and type of work to be done. The permit must be dated and identify the expiration time (usually limited to an 8 to 10 hour shift). 3. Atmospheric Testing - The enclosed space must be tested for the following prior to and during any entry: (a) Oxygen Content - The oxygen content must be between 19.5 and 22.0at all of the lower explosive limit). (b) Flammability - The atmosphere must be nonexplosive (i.e. less than 10of the lower explosive limit). (c) Toxicity - The atmosphere must be tested to ensure the absence of toxic concentration of vapors. 4. Ventilation - A system of positive ventilation must be provided, prior to and during the entire entry period, through the use of fans, portavents, air movers, or by adequate natural drafts. 5. Personal protective equipment - personal protective equipment is not an adequate substitute for safe working conditions, adequate ventilation, or safe working practices. Personal protective equipment can include, but is not limited to, an approved respirator which provides an appropriate level of protection, hard hat, safety glasses (or goggles), gloves, and appropriate full body covering. 6. Area Safety Equipment - Any person entering the enclosed area must be fitted with a safety harness and lifeline. The lifeline must be secured outside the entrance. A hoisting device or other effective means must be provided to lift employees out of the space. 7. Safety Standby Personnel - An additional person(s) must be available at the confined area entrance and in the sight of the personnel inside at all times. Standby personnel must be equipped with proper safety equipment and adequate communication equipment to summon additional help if necessary. Standby personnel must not enter the enclosed area without appropriate safety and personal protective equipment and additional standby personnel must be present at the time of entry.
Recent events (2)
- · F (S) $20000.00
- · Z (W) $24500.00
1910.134 A02
- Issued
- Mar 22, 1993
- Abate by
- Apr 5, 1993
- Penalty
- Initial $24,500 · Current $20,000 Reduced
Recent events (2)
- · F (S) $20000.00
- · Z (W) $24500.00
1910.134 B01
- Issued
- Mar 22, 1993
- Abate by
- Apr 5, 1993
- Penalty
- Initial $24,500 · Current $20,000 Reduced
Recent events (2)
- · F (S) $20000.00
- · Z (W) $24500.00
1910.134 B02
- Issued
- Mar 22, 1993
- Abate by
- Apr 5, 1993
Recent events (2)
- · F (S)
- · Z (W)
1910.134 E03
- Issued
- Mar 22, 1993
- Abate by
- Apr 5, 1993
Recent events (2)
- · F (S)
- · Z (W)
1926.21 B06 I
- Issued
- Mar 22, 1993
- Abate by
- Apr 5, 1993
- Penalty
- Initial $24,500 · Current $10,000 Reduced
Recent events (2)
- · F (S) $10000.00
- · Z (W) $24500.00
More inspections at M.F. Bank the Restoration CO.
View M.F. Bank the Restoration CO.'s full OSHA safety record →
More inspections in this industry (NAICS 000000)
More inspections in PA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 18252999.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.