LAKE WORTH, FL ·
OSHA Inspection: C. & D. CONSTRUCTION
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of C. & D. CONSTRUCTION in 4670 ROYAL DEVON WAY, LAKE WORTH, FL 33467 (NAICS 000000). OSHA activity number 18291781.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- C. & D. CONSTRUCTION
- Site address
- 4670 ROYAL DEVON WAY
- City
- LAKE WORTH
- State
- FL
- ZIP
- 33467
- Mailing
- 1910 SW 67TH TERRACE, POMPANO BEACH, FL 33068
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- Non-union (B)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Data loaded
Establishment context
- NAICS code
- 000000
- SIC code (legacy)
- 1751
- Employees
- 8
- Ownership type
- Private (A)
- Industry flags
- Construction safety.
Citations
14 citations on file for this inspection.
5(a)(1)
- Issued
- Dec 27, 1989
- Abate by
- Jan 2, 1990
- Penalty
- Initial $640 · Current $640
General-duty citation text
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to: (a) The hazards of being struck by falling trusses at building 4670 Royal Devon Way, Lake Worth, Florida 33467: in that adequate and continuous lateral bracing and proper diagonal bracing was not used to prevent; toppling and dominoing of erected trusses. Bracing through chords laterally and cross bracing was not provided to ensure that trusses were secure in a straight and plum position on or about November 2, 1989. Among other methods one feasible and acceptable abatement method to correct this hazard is to install bracing in accordance with the Truss Plate Institute. BWT-76 Bracing Wood Trusses Cemmentary and Recommendations.
1926.20 B01
- Issued
- Dec 27, 1989
- Abate by
- Jan 4, 1990
- Penalty
- Initial $640 · Current $640
1926.20 B02
- Issued
- Dec 27, 1989
- Abate by
- Jan 2, 1990
1926.21 B02
- Issued
- Dec 27, 1989
- Abate by
- Jan 2, 1990
1926.450 A01
- Issued
- Dec 27, 1989
- Abate by
- Jan 2, 1990
- Penalty
- Initial $250 · Current $250
1926.450 B12
- Issued
- Dec 27, 1989
- Abate by
- Jan 2, 1990
1926.28 A
- Issued
- Dec 27, 1989
- Abate by
- Jan 2, 1990
1926.51 A03
- Issued
- Dec 27, 1989
- Abate by
- Jan 2, 1990
1926.100 A
- Issued
- Dec 27, 1989
- Abate by
- Jan 2, 1990
1926.152 A01
- Issued
- Dec 27, 1989
- Abate by
- Jan 6, 1990
1926.59 E01
- Issued
- Dec 27, 1989
- Abate by
- Feb 1, 1990
1926.59 F05 II
- Issued
- Dec 27, 1989
- Abate by
- Feb 1, 1990
1926.59 G01
- Issued
- Dec 27, 1989
- Abate by
- Feb 1, 1990
1926.59 H
- Issued
- Dec 27, 1989
- Abate by
- Feb 1, 1990
More inspections at C. & D. Construction
View C. & D. Construction's full OSHA safety record →
More inspections in this industry (NAICS 000000)
More inspections in FL
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 18291781.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.