WARNER ROBINS, GA —
OSHA Inspection: R. D. SMITH CONSTRUCTION COMPANY, INC.
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of R. D. SMITH CONSTRUCTION COMPANY, INC. in ROBINS AIRFORCE BASE, WARNER ROBINS, GA 31009 (NAICS 000000). OSHA activity number 18343798.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- R. D. SMITH CONSTRUCTION COMPANY, INC.
- Site address
- ROBINS AIRFORCE BASE
- City
- WARNER ROBINS
- State
- GA
- ZIP
- 31009
- Mailing
- POST OFFICE BOX 119, GRIFFIN, GA 30224
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- N
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 000000
- SIC code (legacy)
- 1791
- Employees
- 8
- Ownership type
- A
- Industry flags
- Manufacturing safety.
Citations
2 citations on file for this inspection.
1926.21 B02
- Issued
- Apr 30, 1990
- Abate by
- May 3, 1990
- Penalty
- Initial $280 · Current $280
5(a)(1)
- Issued
- Apr 30, 1990
- Abate by
- May 3, 1990
- Penalty
- Initial $9,000 · Current $9,000
General-duty citation text
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to: a) Warner Robins Air Force Base (Depot Aircraft Hangar site)-During the erection of the pre-fabricated structural steel for the North hangar (64' eave height and 250 foor clear span), temporary bracing was not installed on the North and South side walls, columns #5 through #11, exposing employees to the hazard of being struck by falling materials during structural collapse, on or about January 29, 1990. Among other methods, one feasible and acceptable method to correct this hazard is to permanently brace each beam prior to moving to the next, or to provide adequate temporary bracing until the permanent bracing is installed, according to the manufacturer's instructions.
More inspections at R. D. Smith Construction Company, INC.
View R. D. Smith Construction Company, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 000000)
More inspections in GA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 18343798.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.