Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,191,871Inspections Most recent open 2026-07-30 Last loaded 2026-08-03

OSHA Inspection: HOLSTON DEFENSE CORP

Accident-driven inspection · Safety discipline

On , OSHA opened an accident-driven safety inspection of HOLSTON DEFENSE CORP in BUILDING E4-E6 WEST STONE DRIVE, KINGSPORT, TN 37660 (NAICS 000000). OSHA activity number 18395483.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Holston Defense Corp for free Get an email when a new federal OSHA severe-injury report for Holston Defense Corp is published. One employer, no account, unsubscribe in one click.
Site address
BUILDING E4-E6 WEST STONE DRIVE
City
KINGSPORT
State
TN
ZIP
37660
Inspection type
Accident-driven (A)
Scope
Partial (B)
Discipline
Safety
Advance notice
Yes
Union status
B
Opened
Closing conference
Case closed
Data loaded
NAICS code
000000
SIC code (legacy)
2892
Employees
1158
Ownership type
A
Industry flags
Manufacturing safety.

7 citations on file for this inspection.

5(a)(1)

Serious Gravity 09 1 instance 10 exposed
Issued
Oct 20, 1989
Abate by
Oct 24, 1989
Penalty
Initial $810 · Current $810
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The
employer did not furnish employment and a place of employment which were
free from recognized hazards that were causing or likely to cause death
or serious physical harm to employees in that employees were exposed to:
a) The hazards of heated acetic acid on or about April 21, 1989, in the
event they activate the agitator of tank 15 after the acid has been
steam heated. The tank was filled with acid above the 75% capacity
level required by SOP#1130-3611-A andthe manhole was inadequately
covered.
Among other methods, one feasible and acceptable abatement method to
correct this hazard is to follow the procedure set forth in the SOP
which states, "the tank must be filled to the 75% level of capacity and
that the agitator must be started prior to heating the acid.

1910.109 G02 IIA

Serious Gravity 08 2 instances 10 exposed
Issued
Oct 20, 1989
Abate by
Nov 24, 1989
Penalty
Initial $720
Recent events (2)
  • · A (S)
  • · Z (S) $720.00

1910.132 A

Serious Gravity 07 1 instance 1 exposed
Issued
Oct 20, 1989
Abate by
Oct 24, 1989
Penalty
Initial $630 · Current $630

1910.134 B05

Serious Gravity 04 3 instances 10 exposed
Issued
Oct 20, 1989
Abate by
Oct 24, 1989
Penalty
Initial $360 · Current $360

1910.134 B07

Serious Gravity 04 1 instance 10 exposed
Issued
Oct 20, 1989
Abate by
Oct 24, 1989

1910.151 C

Serious Gravity 07 3 instances 1 exposed
Issued
Oct 20, 1989
Abate by
Nov 8, 1989
Penalty
Initial $630 · Current $630

1910.307 B

Serious Gravity 07 1 instance 10 exposed
Issued
Oct 20, 1989
Abate by
Nov 24, 1989
Penalty
Initial $630
Recent events (2)
  • · A (S)
  • · Z (S) $630.00

View Holston Defense Corp's full OSHA safety record →