CINCINNATI, OH ·
OSHA Inspection: CORRUGATED PARTITIONS, INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of CORRUGATED PARTITIONS, INC. in 296 CIRCLE FREEWAY DR., CINCINNATI, OH 45246 (NAICS 000000). OSHA activity number 2367183.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- CORRUGATED PARTITIONS, INC.
- Site address
- 296 CIRCLE FREEWAY DR.
- City
- CINCINNATI
- State
- OH
- ZIP
- 45246
- Mailing
- 296 CIRCLE FREEWAY DR., CINCINNATI, OH 45246
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- A
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Data loaded
Establishment context
- NAICS code
- 000000
- SIC code (legacy)
- 2653
- Employees
- 40
- Ownership type
- A
- Industry flags
- Manufacturing safety.
Citations
15 citations on file for this inspection.
5(a)(1)
- Issued
- Jan 6, 1986
- Abate by
- Jan 9, 1986
- Penalty
- Initial $560 · Current $300 Reduced
General-duty citation text
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to: a) Employee(s) were exposed to the inadvertent activation of machines that were not locked out during set-up operations and/or trouble- shooting jams. Essentials of an adequate lockout program would include the following: ESSENTIALS OF A LOCKOUT PROGRAM 1) Before any maintenance, inspection, cleaning, adjusting or servicing of equipment (electrical, mechanical or other) that requires entrance into or close contact with the machinery or equipment, the main power disconnect switch or valve, or both, controlling its source of power or flow of materials, shall be lockout out or blocked off with padlock, blank flange or similar device. Residual energy in equipment having systems such as pneumatic, hydraulic, compressed springs or other shall have these systems bled off, blocked or other effective means implemented to ensure that all sources of energy have been deactivated. Prior to any work commencing, however, it must be verified that the equipment has been rendered safe (either by the use of electrical test equipment or by attempting to activate the equipment). 2) Locks keyed separately to ensure removal only by the authorized person shall be provided to each person working in the areas requiring a lockout. Where more than one person is involved in a single operation, or where multiple operations (such as both electrical and mechanical maintenance) are being simultaneously performed on a single piece of equipment, locks shall be used by each person. 3) A written lockout policy shall be established including procedures for lockout out equipment or machinery. Employees involved in implementing the program shall be trained in all elements thereof. 4) There shall be regular enforcement and periodic evaluation of the program to ensure usage and adequacy of the program.
Recent events (2)
- · I (S) $300.00
- · Z (S) $560.00
1910.212 A01
- Issued
- Dec 12, 1985
- Abate by
- Feb 15, 1986
- Penalty
- Initial $350 · Current $175 Reduced
Recent events (2)
- · I (S) $175.00
- · Z (S) $350.00
1910.219 E01 I
- Issued
- Dec 12, 1985
- Abate by
- Jan 12, 1986
- Penalty
- Initial $280 · Current $140 Reduced
Recent events (2)
- · I (S) $140.00
- · Z (S) $280.00
1910.219 E03 I
- Issued
- Dec 12, 1985
- Abate by
- Feb 15, 1986
- Penalty
- Initial $280 · Current $140 Reduced
Recent events (2)
- · I (S) $140.00
- · Z (S) $280.00
1910.303 B01
- Issued
- Dec 12, 1985
- Abate by
- Feb 15, 1986
- Penalty
- Initial $560 · Current $280 Reduced
Recent events (2)
- · I (S) $280.00
- · Z (S) $560.00
1910.304 F04
- Issued
- Dec 12, 1985
- Abate by
- Dec 15, 1985
- Penalty
- Initial $350 · Current $175 Reduced
Recent events (2)
- · I (S) $175.00
- · Z (S) $350.00
1910.304 F05 V
- Issued
- Dec 12, 1985
- Abate by
- Dec 15, 1985
- Penalty
- Initial $490 · Current $245 Reduced
Recent events (2)
- · I (S) $245.00
- · Z (S) $490.00
1903.2 A01
- Issued
- Dec 12, 1985
- Abate by
- Dec 16, 1985
1910.36 B08
- Issued
- Dec 12, 1985
- Abate by
- Jan 12, 1986
1910.151 B
- Issued
- Dec 12, 1985
- Abate by
- Feb 15, 1986
Recent events (2)
- · I (O)
- · Z (O)
1910.215 B09
- Issued
- Dec 12, 1985
- Abate by
- Dec 16, 1985
1910.215 C06 I
- Issued
- Dec 12, 1985
- Abate by
- Dec 16, 1985
1910.303 F
- Issued
- Dec 12, 1985
- Abate by
- Dec 16, 1985
1910.303 G02 II
- Issued
- Dec 12, 1985
- Abate by
- Dec 16, 1985
1910.304 A02
- Issued
- Dec 12, 1985
- Abate by
- Dec 16, 1985
More inspections at Corrugated Partitions, INC.
View Corrugated Partitions, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 000000)
More inspections in OH
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 2367183.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.