WEST HARTFORD, CT —
OSHA Inspection: HOLO-KROME COMPANY
Referral inspection · Health discipline
At a glance
On , OSHA opened a referral health inspection of HOLO-KROME COMPANY in 31 BROOK STREET, WEST HARTFORD, CT 06110 (NAICS 000000). OSHA activity number 300080033.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- HOLO-KROME COMPANY
- Site address
- 31 BROOK STREET
- City
- WEST HARTFORD
- State
- CT
- ZIP
- 06110
- Mailing
- P.O. BOX 333100, WEST HARTFORD, CT 06110
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Health
- Advance notice
- No
- Union status
- N
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 000000
- SIC code (legacy)
- 3452
- Employees
- 330
- Ownership type
- A
Citations
3 citations on file for this inspection.
5(a)(1)
- Issued
- Feb 26, 1997
- Abate by
- Mar 24, 1997
- Penalty
- Initial $5,000 · Current $2,000 Reduced
General-duty citation text
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to aluminum dust/sludge: BRONZE TEAM, METAL POLISHING AREA, RAND BRIGHT MACHINE: THE COMPANY HAD NOT DESIGNED AND INSTALLED AN ADEQUATE ALUMINUM DUST/SLUDGE COLLECTION SYSTEM WHERE ALUMINUM PARTS ARE POLISHED AND BUFFED. AMONG OTHER METHODS, ONE FEASIBLE AND ACCEPTABLE ABATEMENT METHOD TO CORRECT THIS HAZARD IS TO: A.PROVIDE DUCTS WHICH ARE DESIGNED TO MAINTAIN A VELOCITY OF NOT LESS THAN 4500 FT/MIN TO ENSURE THE PROPER TRANSPORT OF COARSE AND FINE PARTICLES. THE DUCTS MUST BE AS SHORT, STRAIGHT AND WITH AS FEW BENDS AND IRREGULARITIES AS POSSIBLE. THE DUCTS SHALL BE CONSTRUCTED OF METAL AND ASSEMBLED WITH SMOOTH INTERIOR SURFACES, AND THE ENTIRE SYSTEM SHALL BE BONDED AND GROUNDED TO MINIMIZE THE ACCUMULATION OF STATIC ELECTRIC CHARGE. B.THE DUCT SYSTEM SHALL BE INSPECTED AND CLEANED FREQUENTLY TO PREVENT BUILDUP OF COMBUSTIBLE DEPOSITS OF METAL DUSTS ON THE INTERIOR SURFACES OF THE DUCT. CLEANUP SHALL BE PERFORMED WITH A SOFT BRUSH OR SQUEEGEE AND PICKUP SHALL BE DONE WITH NON SPARKING SCOOPS. CONDUCTIVE TOOLS SUCH AS A PUTTY KNIFE WHICH HAD BEEN USED TO CHIP AWAY MATERIAL WHICH HAD BECOME SOLIDIFIED WITHIN THE EXHAUST SYSTEM SHALL NOT BE USED. SLUDGE SHALL BE REMOVED FROM THE COLLECTOR ON A DAILY BASIS, PLACED IN A COVERED, VENTED METAL CONTAINER AND PROMPTLY DISPOSED OF IN ACCORDANCE WITH FEDERAL, STATE AND LOCAL REQUIREMENTS. C.PROVIDE AND CONVENIENTLY LOCATE CLASS D FIRE EXTINGUISHERS IN AND AROUND ALUMINUM FINISHING AREAS.
Recent events (2)
- — I (S) $2000.00
- — Z (S) $5000.00
1910.102 A
- Issued
- Feb 26, 1997
- Abate by
- Mar 3, 1997
1910.242 B
- Issued
- Feb 26, 1997
- Abate by
- Mar 4, 1997
More inspections at Holo-Krome Company
View Holo-Krome Company's full OSHA safety record →
More inspections in this industry (NAICS 000000)
More inspections in CT
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 300080033.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.