Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: FUELCELL ENERGY, INC.

Referral inspection · Health discipline

On , OSHA opened a referral health inspection of FUELCELL ENERGY, INC. in 539 TECHNOLOGY PARK DRIVE, TORRINGTON, CT 06790 (NAICS 000000). OSHA activity number 300086352.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Fuelcell Energy, INC. — free Get an email when a new federal OSHA severe-injury report for Fuelcell Energy, INC. is published. One employer, no account, unsubscribe in one click.
Site address
539 TECHNOLOGY PARK DRIVE
City
TORRINGTON
State
CT
ZIP
06790
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
N
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
000000
SIC code (legacy)
3629
Employees
120
Ownership type
A
Industry flags
Manufacturing health.

1 citation on file for this inspection.

5(a)(1)

Deleted Serious Gravity 10 1 instance 5 exposed
Issued
Feb 22, 2002
Abate by
Apr 10, 2002
Penalty
Initial $3,500 · Current $3,500
Section 5(a)(1) of the Occupational Safety and Health Act of 1970:  The
employer did not
furnish employment and a place of employment which were free from
recognized hazards that
were causing or likely to cause death or serious physical harm to
employees in that employees
were exposed to the potential of a fire and/or explosion created by
flammable vapors:
CASTING ROOM:  ON OR ABOUT 1/14/02 AN EXPLOSION OCCURRED IN THE LARGE
CASTING MACHINE AND ASSOCIATED VENTILATION SYSTEM.
AMONG OTHER METHODS, TWO FEASIBLE AND ACCEPTABEL ABATEMENT
METHODS TO CORRECT THIS HAZARD ARE T0:
1.DESIGN AND INSTALL EXPLOSION RELIEF VENTING IN THE CASTING MACHINE. SEE
NATIONAL FIRE PROTECTION ASSOCIATION "STANDARD
FOR OVENS AND FURNACES" NFPA 86 SECTION 3-3.
2.INSTALL ELECTRICAL INTERLOCKS AND FLOW SWITCHES IN THE SAFETY
CONTROL CIRCUIT SO THAT LOSS OF VENTILATION OR AIRFLOW
IMMEDIATELY SHUTS DOWN THE CASTING MACHINE. SEE NATIONAL FIRE
PROTECTION ASSOCIATION "STANDARD FOR OVENS AND FURNACES" NFPA
86 SECTION 5-5.
Recent events (2)
  • — I (S) $3500.00
  • — Z (S) $3500.00

View Fuelcell Energy, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 300086352.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.