Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: ALL STATE FABRICATORS CORP

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of ALL STATE FABRICATORS CORP in 1485 ELMWOOD AVE., CRANSTON, RI 02910 (NAICS 000000). OSHA activity number 300090107.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch ALL State Fabricators Corp — free Get an email when a new federal OSHA severe-injury report for ALL State Fabricators Corp is published. One employer, no account, unsubscribe in one click.
Site address
1485 ELMWOOD AVE.
City
CRANSTON
State
RI
ZIP
02910
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
N
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
000000
SIC code (legacy)
3444
Employees
55
Ownership type
A

2 citations on file for this inspection.

5(a)(1)

Serious Gravity 10 1 instance 3 exposed
Issued
May 21, 1996
Abate by
Jun 25, 1996
Penalty
Initial $2,500 · Current $1,250 Reduced
Section 5(a)(1) of the Occupational Safety and Health Act of 1970:
The employer did not furnish employmnent and a place of employment
which were free from recognized hazards that were causing or likely
to cause death or serious physical harm to employees in that
employees were exposed to the hazard of being struck by an
inadequately secured ceiling panel of a Smart Box while working
underneath it on or about 5/20/96.
(a) Establishment:  During disassembly of a Smart Box, four
bolts which hold the ceiling panel in place were removed prior to
securing the panel to ensure that it would not fall down onto the
employees.
Among other methods, one feasible and acceptable method of
abatement would be to develop, implement, and enforce the use of a
formal procedure for safely disassembling these pieces of
equipment.  Before the ceiling panel bolts are removed, the panel
could be secured in place by the use of a sling attached to an
overhead crane.  The panel could then be lowered to the ground
safely after the bolts are removed.
Recent events (2)
  • — I (S) $1250.00
  • — Z (S) $2500.00

1910.147 C04 II

Other-than-serious Gravity 01 1 instance 50 exposed
Issued
May 21, 1996
Abate by
Jun 25, 1996

View ALL State Fabricators Corp's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 300090107.