PROVIDENCE, RI —
OSHA Inspection: VENDA RAVIOLI INC.
Referral inspection · Health discipline
At a glance
On , OSHA opened a referral health inspection of VENDA RAVIOLI INC. in RATHBONE ST, PROVIDENCE, RI 02903 (NAICS 000000). OSHA activity number 300091998.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- VENDA RAVIOLI INC.
- Site address
- RATHBONE ST
- City
- PROVIDENCE
- State
- RI
- ZIP
- 02903
- Mailing
- 265 ATWELLS AV, PROVIDENCE, RI 02903
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Complete (A)
- Discipline
- Health
- Advance notice
- No
- Union status
- N
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Data loaded
Establishment context
- NAICS code
- 000000
- SIC code (legacy)
- 5421
- Employees
- 20
- Ownership type
- A
Citations
6 citations on file for this inspection.
5(a)(1)
- Issued
- Apr 15, 1997
- Abate by
- May 20, 1997
- Penalty
- Initial $1,250 · Current $625 Reduced
0530
General-duty citation text
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employmnent and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to carbon dioxide levels in excess of the National Institute for Occupational Safety and Health (NIOSH) and the American Conference of Governmental Industrial Hygienists (ACGIH) recommended short term exposure limit (STEL) of 30,000 parts per million (ppm) over a fifteen minute period: a) Freezing Tunnel Area: Employees were exposed in excess of the NIOSH and ACGIH recommended STEL of 30,000 parts per million (ppm) carbon dioxide. An exposure of 31781 ppm was documented during a 115 minute sampling period and an exposure of 31703 ppm was documented during a 109 minute sampling period. Abatement Note: Feasible abatement may include but is not necessarily limited to the following: 1.Enhanced local exhaust ventilation at both the intake and output areas of the freezing tunnel. 2.Provision of make-up air to allow for efficient operation of the exhaust ventilation. 3.Use of a floor fan to allow for better air mixing in the plant. 4.Installation, use and maintenance of a carbon dioxide alarm which will warn employees if hazardous STEL levels are being approached. This alarm should be positioned in an area where highest exposures are expected.
Recent events (2)
- — I (S) $625.00
- — Z (S) $1250.00
1910.1000 A02
- Issued
- Apr 15, 1997
- Abate by
- May 20, 1997
1910.1000 E
- Issued
- Apr 15, 1997
- Abate by
- May 20, 1997
0530
1910.132 A
- Issued
- Apr 15, 1997
- Abate by
- May 2, 1997
- Penalty
- Initial $750 · Current $375 Reduced
Recent events (2)
- — I (S) $375.00
- — Z (S) $750.00
1910.1200 E01
- Issued
- Apr 15, 1997
- Abate by
- May 20, 1997
- Penalty
- Initial $1,000 · Current $500 Reduced
Recent events (2)
- — I (S) $500.00
- — Z (S) $1000.00
1910.1200 H
- Issued
- Apr 15, 1997
- Abate by
- May 20, 1997
More inspections at Venda Ravioli INC.
View Venda Ravioli INC.'s full OSHA safety record →
More inspections in this industry (NAICS 000000)
More inspections in RI
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 300091998.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.