Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: T P I COMPOSITES INC

Planned inspection · Health discipline

On , OSHA opened a planned health inspection of T P I COMPOSITES INC in 373 MARKET ST., WARREN, RI 02885 (NAICS 000000). OSHA activity number 300098373.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch T P I Composites INC — free Get an email when a new federal OSHA severe-injury report for T P I Composites INC is published. One employer, no account, unsubscribe in one click.
Site address
373 MARKET ST.
City
WARREN
State
RI
ZIP
02885
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Health
Advance notice
No
Union status
N
Opened
Closing conference
Case closed
Data loaded
NAICS code
000000
SIC code (legacy)
3732
Employees
293
Ownership type
A
Industry flags
Manufacturing health.

6 citations on file for this inspection.

5(a)(1)

Serious Gravity 03 7 instances 10 exposed
Issued
Feb 3, 1999
Abate by
Feb 16, 1999
Penalty
Initial $1,875 · Current $938 Reduced

Hazardous substances 1750

Section 5(a)(1) of the Occupational Safety and Health Act of 1970:  The
employer did not
furnish employment and a place of employment which were free from
recognized hazards that
were causing or likely to cause death or serious physical harm to
employees in that employees
were exposed to the hazards of fire and explosion from the storage and
possible mixing of
flammable liquids with oxidizing materials (organic peroxides):
(a) Various locations on the plant floor, including boat assembly areas,
Bombardier area,
prototype area and special projects area. MEKP was routinely stored in
flammable storage
cabinets with flammable/organic liquids, including styrene formulations,
Gelcoat formulations,
turpentine, alcohol, resin formulations, reactors, adhesives, and spray
solvents.
(b) Outside flammable storage building:  MEKP stored with flammable
materials.
Among other methods, one feasible and acceptable abatement method to
correct
this hazard is
the segregation and separate storage of incompatible chemicals, the use of
appropriate signs
designating the separate storage areas, and employee training to prevent
the inadvertent common
storage of incompatible materials.le
Recent events (2)
  • — I (S) $937.50
  • — Z (S) $1875.00

1910.1200 E01

Other-than-serious Gravity 01 1 instance 10 exposed
Issued
Feb 3, 1999
Abate by
Jul 6, 1999
Recent events (2)
  • — P (O)
  • — Z (O)

1910.1200 F05 I

Other-than-serious Gravity 01 3 instances 10 exposed
Issued
Feb 3, 1999
Abate by
May 4, 1999

1910.132 D02

Other-than-serious Gravity 01 1 instance 10 exposed
Issued
Feb 3, 1999
Abate by
Sep 10, 1999
Recent events (2)
  • — I (O)
  • — Z (O)

1910.106 D07 I

Other-than-serious Gravity 01 1 instance 5 exposed
Issued
Feb 3, 1999
Abate by
Feb 16, 1999

1910.106 E09 I

Other-than-serious Gravity 01 1 instance
Issued
Feb 3, 1999
Abate by
Feb 16, 1999

View T P I Composites INC's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 300098373.