Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: MILLARD WIRE COMPANY

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of MILLARD WIRE COMPANY in 257 INDUSTRIAL DRIVE, WARWICK, RI 02886 (NAICS 000000). OSHA activity number 300099629.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Millard Wire Company — free Get an email when a new federal OSHA severe-injury report for Millard Wire Company is published. One employer, no account, unsubscribe in one click.
Site address
257 INDUSTRIAL DRIVE
City
WARWICK
State
RI
ZIP
02886
Mailing
257 INDUSTRIAL DRIVE, WARWICK, RI 02886
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
N
Opened
Closing conference
Case closed
Data loaded
NAICS code
000000
SIC code (legacy)
3915
Employees
35
Ownership type
A

5 citations on file for this inspection.

5(a)(1)

Serious Gravity 03 1 instance 2 exposed
Issued
Feb 24, 1999
Abate by
Apr 28, 1999
Penalty
Initial $875 · Current $438 Reduced
Section 5(a)(1) of the Occupational Safety and Health Act of 1970:  The
employer did not
furnish employment and a place of employment which were free from
recognized hazards that
were causing or likely to cause death or serious physical harm to
employees in that employees
were exposed to an explosion hazard at the pit furnace retort.  Controls
were not installed to
ensure that the retort circulating fan is turned on at the beginning of
the operating cycle and all
oxygen is adequately purged from the retort prior to adding dissociated
ammonia and lighting
the burn-off tube.  Also, a flame arrestor or other device was not
installed to prevent a flashback
into the retort.  Among other methods, feasible and acceptable abatement
methods to correct this
hazard are to install a system whereby the process cannot continue unless
the circulating fan is
running and the retort has been adequately purged of oxygen.   Also, a
burn-off pigtail or other
flame arresting device shall be installed to prevent flashback into the
retort.  Written operating
procedures for the new system shall be developed and maintained in the
vicinity
of the operation
and affected employees shall be trained in these procedures.
Recent events (2)
  • — I (S) $437.50
  • — Z (S) $875.00

1910.132 D01

Other-than-serious Gravity 01 1 instance 20 exposed
Issued
Feb 24, 1999
Abate by
Apr 14, 1999

1910.132 F01

Other-than-serious Gravity 01 1 instance 20 exposed
Issued
Feb 24, 1999
Abate by
Apr 14, 1999

1910.147 C04 II

Other-than-serious Gravity 01 1 instance 20 exposed
Issued
Feb 24, 1999
Abate by
Apr 28, 1999

1910.147 C07 IV

Other-than-serious Gravity 01 1 instance 20 exposed
Issued
Feb 24, 1999
Abate by
Apr 28, 1999