BROOKLYN, OH —
OSHA Inspection: AREWAY INC.
Referral inspection · Health discipline
At a glance
On , OSHA opened a referral health inspection of AREWAY INC. in 8525 CLINTON ROAD, BROOKLYN, OH 44144 (NAICS 000000). OSHA activity number 300104916.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- AREWAY INC.
- Site address
- 8525 CLINTON ROAD
- City
- BROOKLYN
- State
- OH
- ZIP
- 44144
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Health
- Advance notice
- No
- Union status
- N
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Data loaded
Establishment context
- NAICS code
- 000000
- SIC code (legacy)
- 3471
- Employees
- 200
- Ownership type
- A
Citations
2 citations on file for this inspection.
5(a)(1)
- Issued
- Mar 14, 1997
- Abate by
- Jan 31, 1999
- Penalty
- Initial $1,375 · Current $825 Reduced
General-duty citation text
Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to: A.Employee(s) were exposed to serious hazards that could result in severe burns, concussions, multiple internal injuries and/or death from the hazard of inadequate explosion suppression or proper fire prevention in the dust collection system where aluminum dust and other buffing compound dusts are collected and exhausted to a collection system (bag house) in the back of the facility. On or about February 13, 1997, in the buffing area, a possible fire or spark was produced by a buffing machine(s), where it apparently got into the dust exhaust system. Once this spark or fire got into the exhaust system, it got into the bag house, caused a small explosion, whereupon the dust in the baghouse was shaken loose and another much larger explosion occurred, sending the force of the explosion and a resultant fire back through the exhaust system. The explosive force and fire came out at machines #25, #27, and #42, where two workers at machine #25 were seriously burned, one requiring extensive treatment and hospitalization. The #2 baghouse was destroyed and its associated ductwork was also extensively damaged. Among other methods, one feasible and acceptable abatement method to correct this hazard is to install engineering controls such as those stipulated in NFPA 68- 1994, Guide for Venting of Deflagrations, NFPA 69-1992 Standard on Explosion Prevention Systems, and NFPA 65-1993, Standard for the Processing and Finishing of Aluminum. Essential engineering controls to control this hazard shall include, but not necessarily limited to, the following: 1) The use of a fire/explosion prevention system to prevent the likelihood of ignition of combustible dusts inside process equipment which would result in fire and/or explosion. Examples of such systems could include: a) Cyclone and other dry-type dust collectors shall be equipped with suitable instruments for recording the inside temperature. An over-temperature alarm or warning device shall be included and the limit setting shall be safely below the maximum service temperature of the filter medium or safely below the ignition temperature of the dust layer or dust cloud, whichever is lowest. The alarms and actuating equipment shall be located in a non- hazardous location. All such instruments shall give indication and alarm at easily observed central locations. b) Dust collectors and associated ductwork shall be protected by appropriately sized and constructed explosion vents, anti-flashbackswing valves and/or rupture diaphragms. All relief venting shall discharge outside of the building to a safe location.
Recent events (3)
- — P (S) $825.00
- — F (S) $825.00
- — Z (S) $1375.00
1910.307 B
- Issued
- Mar 14, 1997
- Abate by
- Jun 30, 1998
- Penalty
- Initial $1,100 · Current $660 Reduced
Recent events (2)
- — F (S) $660.00
- — Z (S) $1100.00
More inspections at Areway INC.
View Areway INC.'s full OSHA safety record →
More inspections in this industry (NAICS 000000)
More inspections in OH
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 300104916.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.