OSHA Inspection: AREWAY INC.

Referral inspection · Health discipline

On , OSHA opened a referral health inspection of AREWAY INC. in 8525 CLINTON ROAD, BROOKLYN, OH 44144 (NAICS 000000). OSHA activity number 300104916.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Areway INC. — free Get an email when a new federal OSHA severe-injury report for Areway INC. is published. One employer, no account, unsubscribe in one click.
Establishment
AREWAY INC.
Site address
8525 CLINTON ROAD
City
BROOKLYN
State
OH
ZIP
44144
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
N
Opened
Closing conference
Case closed
Data loaded
NAICS code
000000
SIC code (legacy)
3471
Employees
200
Ownership type
A

2 citations on file for this inspection.

5(a)(1)

Serious Gravity 03 1 instance 20 exposed
Issued
Mar 14, 1997
Abate by
Jan 31, 1999
Penalty
Initial $1,375 · Current $825 Reduced
Section 5(a)(1) of the Occupational Safety and Health Act of 1970:  The
employer did not
furnish employment and a place of employment which were free from
recognized hazards that
were causing or likely to cause death or serious physical harm to
employees in that employees
were exposed to:
A.Employee(s) were exposed to serious hazards that could result in severe
burns,
concussions, multiple internal injuries and/or death from the hazard of
inadequate
explosion suppression or proper fire prevention in the dust collection
system
where aluminum dust and other buffing compound dusts are collected and
exhausted to a collection system (bag house) in the back of the facility.
On or about February 13, 1997, in the buffing area, a possible fire or
spark was
produced by a buffing machine(s), where it apparently got into the dust
exhaust
system.  Once this spark or fire got into the exhaust system, it got into
the
bag
house, caused a small explosion, whereupon the dust in the baghouse was
shaken
loose and another much larger explosion occurred, sending the force of the
explosion and a resultant fire back through the exhaust system.  The
explosive
force and fire came out at machines #25, #27, and #42, where two workers at
machine #25 were seriously burned, one requiring extensive treatment and
hospitalization.  The #2 baghouse was destroyed and its associated
ductwork was
also extensively damaged.
Among other methods, one feasible and acceptable abatement method to
correct
this hazard is to install engineering controls such as those stipulated in
NFPA 68-
1994, Guide for Venting of Deflagrations, NFPA 69-1992 Standard on
Explosion
Prevention Systems, and NFPA 65-1993, Standard for the Processing and
Finishing of Aluminum.  Essential engineering controls to control this
hazard
shall include, but not necessarily limited to, the following:
1)  The use of a fire/explosion prevention system to prevent the likelihood
of ignition of combustible dusts inside process equipment which would
result in fire and/or explosion.  Examples of such systems could include:
a)  Cyclone and other dry-type dust collectors shall be equipped
with suitable instruments for recording the inside temperature.  An
over-temperature alarm or warning device shall be included and
the limit setting shall be safely below the maximum service
temperature of the filter medium or safely below the ignition
temperature of the dust layer or dust cloud, whichever is lowest.
The alarms and actuating equipment shall be located in a non-
hazardous location.  All such instruments shall give indication and
alarm at easily observed central locations.
b)  Dust collectors and associated ductwork shall be protected by
appropriately sized and constructed explosion vents, anti-flashbackswing
valves and/or rupture diaphragms.  All relief venting shall
discharge outside of the building to a safe location.
Recent events (3)
  • — P (S) $825.00
  • — F (S) $825.00
  • — Z (S) $1375.00

1910.307 B

Serious Gravity 02 1 instance 4 exposed
Issued
Mar 14, 1997
Abate by
Jun 30, 1998
Penalty
Initial $1,100 · Current $660 Reduced
Recent events (2)
  • — F (S) $660.00
  • — Z (S) $1100.00

View Areway INC.'s full OSHA safety record →